IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,500

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0293 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,541 $13,500 Implemented
WV0293 # 04 Y:2004 04 2004 DEVELOP A REPAIR/REPLACE POLICY $3,874 $1,250 Implemented
WV0293 # 05 Y:2004 05 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,283 $300 Not Implemented
WV0293 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,232 $4,250 Implemented
WV0293 # 07 Y:2004 07 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,353 $100 Not Implemented
WV0293 # 08 Y:2004 08 2004 INSTALL OCCUPANCY SENSORS $1,935 $400 Not Implemented
WV0293 # 09 Y:2004 09 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,889 $210 Implemented
WV0293 # 10 Y:2004 10 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,815 $3,000 Not Implemented
WV0293 # 11 Y:2004 11 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,657 $300 Implemented
WV0293 # 12 Y:2004 12 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $565 $1,100 Not Implemented
WV0293 # 13 Y:2004 13 2004 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $38,480 $1,900 Not Implemented
WV0290 # 07 Y:2004 07 2004 REPAIR AND ELIMINATE STEAM LEAKS $2,228 $150 Implemented
WV0290 # 08 Y:2004 08 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,107 $300 Implemented
WV0290 # 09 Y:2004 09 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,058 $240 Not Implemented
WV0290 # 10 Y:2004 10 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $404 $0 Implemented
WV0290 # 11 Y:2004 11 2004 REPAIR OR REPLACE STEAM TRAPS $330 $1,600 Implemented
WV0290 # 12 Y:2004 12 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $268 $400 Not Implemented
WV0290 # 13 Y:2004 13 2004 INSULATE BARE EQUIPMENT $140 $62 Implemented
WV0290 # 01 Y:2004 01 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $17,454 $0 Implemented
WV0290 # 02 Y:2004 02 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,220 $21,673 Not Implemented
WV0290 # 03 Y:2004 03 2004 DEVELOP A REPAIR/REPLACE POLICY $7,121 $1,000 Implemented
WV0290 # 04 Y:2004 04 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,392 $8,050 Implemented
WV0290 # 05 Y:2004 05 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,244 $1,800 Not Implemented
WV0290 # 06 Y:2004 06 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,003 $100 Implemented
WV0289 # 01 Y:2004 01 2004 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $46,305 $117,949 Not Implemented