IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,520

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ORS004 # 06 Y:1999 06 1999 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $14,000 $6,360 Not Implemented
ORS004 # 07 Y:1999 07 1999 OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS $10,860 $6,170 Not Implemented
ORS004 # 08 Y:1999 08 1999 OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS $8,525 $1,270 Implemented
ORS004 # 09 Y:1999 09 1999 MINIMIZE WATER USAGE $14,760 $6,800 Implemented
ORS004 # 10 Y:1999 10 1999 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $2,305 $1,725 Not Implemented
ORS004 # 11 Y:1999 11 1999 MINIMIZE WATER USAGE $2,930 $0 Implemented
SF0172 # 15 Y:1999 15 1999 USE UTILITY CONTROLLED POWER MANAGEMENT $1,726 $0 Implemented
SF0172 # 16 Y:1999 16 1999 USE UTILITY CONTROLLED POWER MANAGEMENT $44,655 $23,000 Implemented
SF0172 # 17 Y:1999 17 1999 OPTIMIZE PLANT POWER FACTOR $3,752 $9,602 Not Implemented
SF0172 # 18 Y:1999 18 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $55,537 $10,830 Not Implemented
TN0671 # 01 Y:1999 01 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $250,000 $2,030 Not Implemented
TN0671 # 02 Y:1999 02 1999 INSTALL EQUIPMENT TO MOVE PRODUCT $108,400 $34,670 Not Implemented
TN0671 # 03 Y:1999 03 1999 MODIFY CURRENT INCENTIVE PROGRAM $45,000 $16,375 Not Implemented
TN0671 # 04 Y:1999 04 1999 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $28,195 $1,075 Not Implemented
TN0671 # 05 Y:1999 05 1999 SELL / OFFER BY-PRODUCT AS ANIMAL FEED $21,560 $0 Not Implemented
TN0671 # 06 Y:1999 06 1999 OPTIMIZE PLANT POWER FACTOR $4,000 $13,000 Not Implemented
TN0671 # 07 Y:1999 07 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,680 $11,780 Not Implemented
TN0671 # 08 Y:1999 08 1999 INSTALL / REPAIR INSULATION ON STEAM LINES $360 $305 Not Implemented
NC0176 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $71 $150 Implemented
NC0176 # 02 Y:1999 02 1999 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $180 $640 Not Implemented
NC0176 # 03 Y:1999 03 1999 RECOVER WASTE HEAT FROM EQUIPMENT $639 $1,000 Not Implemented
NC0176 # 04 Y:1999 04 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,080 $5,000 Not Implemented
NC0176 # 05 Y:1999 05 1999 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $242 $300 Implemented
NC0176 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $639 $768 Not Implemented
NC0176 # 07 Y:1999 07 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $450 $300 Implemented