Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0054 # 02 Y:2003 | 02 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $185 | $130 | n/a |
UU0054 # 03 Y:2003 | 03 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,707 | $0 | n/a |
UU0054 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $1,487 | $720 | n/a |
UU0054 # 05 Y:2003 | 05 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,909 | $3,500 | n/a |
UU0054 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $868 | $10,415 | n/a |
UU0054 # 07 Y:2003 | 07 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,752 | $0 | n/a |
SU0166 # 01 Y:2003 | 01 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,012 | $232 | Not Implemented |
SU0166 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,388 | $480 | Not Implemented |
SU0166 # 03 Y:2003 | 03 | 2003 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $28,125 | $10,016 | Implemented |
SU0166 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,270 | $24,797 | Not Implemented |
SU0166 # 05 Y:2003 | 05 | 2003 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $24,000 | $19,912 | Not Implemented |
SU0166 # 06 Y:2003 | 06 | 2003 | USE EXISTING DAM TO GENERATE ELECTRICITY | $49,025 | $132,000 | Not Implemented |
SU0166 # 07 Y:2003 | 07 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,000 | $68,560 | Implemented |
LE0171 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $12,638 | $0 | Implemented |
LE0171 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,790 | $0 | Not Implemented |
LE0171 # 03 Y:2003 | 03 | 2003 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,645 | $6,000 | Implemented |
LE0171 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $2,512 | $0 | Not Implemented |
LE0171 # 05 Y:2003 | 05 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,863 | $608 | Implemented |
LE0171 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,050 | $10,345 | Not Implemented |
LE0171 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $1,080 | $375 | Not Implemented |
LE0171 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $664 | $100 | Implemented |
UF0329 # 01 Y:2003 | 01 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $211,005 | $255,000 | n/a |
UF0329 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,225 | $16,573 | n/a |
UF0329 # 03 Y:2003 | 03 | 2003 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $11,417 | $0 | n/a |
UF0329 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $12,931 | $0 | n/a |