Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,302
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0379 # 01 Y:2008 | 01 | 2008 | ADJUST BURNERS FOR EFFICIENT OPERATION | $871 | $800 | Implemented |
NC0379 # 02 Y:2008 | 02 | 2008 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $333 | $100 | Implemented |
NC0379 # 03 Y:2008 | 03 | 2008 | REDUCE VENTILATION AIR | $7,706 | $25,500 | Not Implemented |
NC0379 # 04 Y:2008 | 04 | 2008 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,284 | $3,000 | Implemented |
NC0379 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $237 | $50 | Implemented |
NC0379 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $269 | $100 | Implemented |
NC0379 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $101 | $308 | Implemented |
NC0379 # 08 Y:2008 | 08 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $834 | $1,728 | Implemented |
GT0852 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,327 | $3,500 | Implemented |
GT0852 # 02 Y:2008 | 02 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,774 | $0 | Implemented |
GT0852 # 03 Y:2008 | 03 | 2008 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $9,073 | $9,000 | Not Implemented |
GT0852 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $790 | $2,775 | Not Implemented |
GT0852 # 05 Y:2008 | 05 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $9,500 | $15,600 | Not Implemented |
GT0852 # 06 Y:2008 | 06 | 2008 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $22,600 | $60,000 | Not Implemented |
GT0852 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,667 | $37,500 | Implemented |
GT0852 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,037 | $64,132 | Not Implemented |
LE0274 # 01 Y:2008 | 01 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $18,751 | $1,800 | Not Implemented |
LE0274 # 02 Y:2008 | 02 | 2008 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,058 | $10,000 | Not Implemented |
LE0274 # 03 Y:2008 | 03 | 2008 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,438 | $7,000 | Not Implemented |
LE0274 # 04 Y:2008 | 04 | 2008 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $2,421 | $4,680 | Implemented |
LE0274 # 05 Y:2008 | 05 | 2008 | USE SYNTHETIC LUBRICANT | $1,064 | $500 | Implemented |
LE0274 # 06 Y:2008 | 06 | 2008 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $189 | $280 | Implemented |
LE0274 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,227 | $18,236 | Not Implemented |
LE0274 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $1,642 | $360 | Not Implemented |
UW0021 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $52,486 | $175,000 | Not Implemented |