Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,304
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0823 # 04 Y:2010 | 04 | 2010 | INSTALL WIND POWERED ELECTRIC GENERATOR | $1,820,272 | $1,400,000 | Not Implemented |
UD0823 # 05 Y:2010 | 05 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $26,291 | $98,085 | Not Implemented |
UD0823 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $17,201 | $7,375 | Implemented |
UD0823 # 07 Y:2010 | 07 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $21,736 | $125 | Not Implemented |
UD0823 # 08 Y:2010 | 08 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,268 | $25 | Implemented |
UD0823 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $500 | Not Implemented |
UD0823 # 10 Y:2010 | 10 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $524 | $25 | Implemented |
UD0823 # 11 Y:2010 | 11 | 2010 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $19,629 | $7,500 | Not Implemented |
UD0823 # 12 Y:2010 | 12 | 2010 | USE OPTIMUM TEMPERATURE | $3,244 | $63 | Not Implemented |
UD0823 # 13 Y:2010 | 13 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,010 | $50,050 | Implemented |
UD0823 # 14 Y:2010 | 14 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,832 | $9,160 | Not Implemented |
UD0823 # 15 Y:2010 | 15 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $355 | $25 | Implemented |
MI0193 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $159,261 | $64,000 | Not Implemented |
MI0193 # 02 Y:2010 | 02 | 2010 | HEAT WATER WITH EXHAUST HEAT | $100,762 | $23,000 | Implemented |
MI0193 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $58,162 | $63,083 | Implemented |
MI0193 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,000 | $1,210 | Implemented |
MI0193 # 05 Y:2010 | 05 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,004 | $40 | Implemented |
MI0193 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $6,565 | $4,531 | Not Implemented |
MI0193 # 07 Y:2010 | 07 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,182 | $1,750 | Implemented |
UD0822 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $609 | $609 | Not Implemented |
UD0822 # 02 Y:2010 | 02 | 2010 | INSTALL WIND POWERED ELECTRIC GENERATOR | $244,092 | $1,216,000 | Not Implemented |
UD0822 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,399 | $8,760 | Not Implemented |
UD0822 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,724 | $24,375 | Not Implemented |
UD0822 # 05 Y:2010 | 05 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $677 | $125 | Not Implemented |
UD0822 # 06 Y:2010 | 06 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,400 | $2,000 | Not Implemented |