Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,317
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0282 # 04 Y:2004 | 04 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,151 | $0 | Implemented |
WV0282 # 05 Y:2004 | 05 | 2004 | BURN WASTE OIL FOR HEAT | $6,148 | $3,760 | Not Implemented |
WV0282 # 06 Y:2004 | 06 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $3,646 | $1,140 | Implemented |
WV0282 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,390 | $4,448 | Implemented |
WV0282 # 08 Y:2004 | 08 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,521 | $490 | Not Implemented |
WV0282 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,387 | $250 | Implemented |
WV0282 # 10 Y:2004 | 10 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $923 | $715 | Implemented |
WV0282 # 11 Y:2004 | 11 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $788 | $614 | Not Implemented |
WV0282 # 12 Y:2004 | 12 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,784 | $76 | Implemented |
WV0282 # 13 Y:2004 | 13 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,534 | $250 | Not Implemented |
WV0282 # 14 Y:2004 | 14 | 2004 | ISOLATE HOT OR COLD EQUIPMENT | $5,688 | $690 | Implemented |
WV0281 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $1,163 | $38 | Implemented |
WV0281 # 01 Y:2003 | 01 | 2003 | BURN A LESS EXPENSIVE GRADE OF FUEL | $52,226 | $153,000 | Not Implemented |
WV0281 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $12,150 | $1,695 | Not Implemented |
WV0281 # 03 Y:2003 | 03 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $1,940 | $240 | Implemented |
WV0281 # 04 Y:2003 | 04 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,652 | $1,000 | Implemented |
WV0280 # 01 Y:2003 | 01 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $143,927 | $209,000 | Not Implemented |
WV0280 # 02 Y:2003 | 02 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $78,750 | $1,000 | Implemented |
WV0280 # 03 Y:2003 | 03 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $63,438 | $8,180 | Not Implemented |
WV0280 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $27,160 | $750 | Implemented |
WV0280 # 05 Y:2003 | 05 | 2003 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,943 | $45,000 | Not Implemented |
WV0280 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,252 | $750 | Implemented |
WV0280 # 07 Y:2003 | 07 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,348 | $100 | Implemented |
WV0280 # 08 Y:2003 | 08 | 2003 | BURN WASTE OIL FOR HEAT | $4,718 | $3,500 | Not Implemented |
WV0280 # 09 Y:2003 | 09 | 2003 | USE SYNTHETIC LUBRICANT | $4,705 | $250 | Implemented |