Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,708

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0035 # 07 Y:2002 07 2002 REPAIR AND ELIMINATE STEAM LEAKS $720 $2,145 Not Implemented
TA0035 # 08 Y:2002 08 2002 RECOVER AND REUSE WASTE MATERIAL $762 $0 Implemented
TA0035 # 09 Y:2002 09 2002 INCREASE USE OF AUTOMATION $561 $87 Not Implemented
WV0249 # 01 Y:2002 01 2002 USE OPTIMUM THICKNESS INSULATION $5,252 $1,650 Implemented
WV0249 # 02 Y:2002 02 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $5,366 $440 Implemented
WV0249 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,995 $7,711 Not Implemented
WV0249 # 04 Y:2002 04 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,868 $550 Implemented
WV0249 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,077 $88 Implemented
WV0249 # 06 Y:2002 06 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,390 $268 Not Implemented
WV0249 # 07 Y:2002 07 2002 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $926 $660 Not Implemented
WV0249 # 08 Y:2002 08 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,799 $200 Implemented
WV0249 # 09 Y:2002 09 2002 INSTALL OCCUPANCY SENSORS $535 $750 Implemented
WV0249 # 10 Y:2002 10 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,191 $2,460 Not Implemented
WV0249 # 11 Y:2002 11 2002 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $600 $1,240 Not Implemented
WV0249 # 12 Y:2002 12 2002 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $672 $200 Implemented
WV0249 # 13 Y:2002 13 2002 INSTALL AUTOMATIC PACKING EQUIPMENT $67,320 $55,000 Not Implemented
WV0248 # 01 Y:2002 01 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,103 $140 Not Implemented
WV0248 # 02 Y:2002 02 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $934 $34 Implemented
WV0248 # 03 Y:2002 03 2002 USE OPTIMUM THICKNESS INSULATION $5,194 $840 Implemented
WV0248 # 04 Y:2002 04 2002 INSULATE BARE EQUIPMENT $10,209 $316 Implemented
WV0248 # 05 Y:2002 05 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $14,097 $340 Implemented
WV0248 # 06 Y:2002 06 2002 INSTALL OCCUPANCY SENSORS $1,454 $600 Implemented
WV0248 # 07 Y:2002 07 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,421 $850 Implemented
WV0248 # 08 Y:2002 08 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $534 $1,660 Implemented
WV0248 # 09 Y:2002 09 2002 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $14,002 $0 Not Implemented