IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,105

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0668 # 05 Y:2003 05 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $67,238 $0 Implemented
OK0668 # 06 Y:2003 06 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $21,821 $1,125 Implemented
OK0668 # 07 Y:2003 07 2003 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $50,260 $51,780 Not Implemented
OK0668 # 08 Y:2003 08 2003 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $31,772 $9,500 Not Implemented
OK0668 # 09 Y:2003 09 2003 INSULATE BARE EQUIPMENT $1,369 $1,455 Implemented
OK0668 # 10 Y:2003 10 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,501 $6,296 Not Implemented
OK0668 # 11 Y:2003 11 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $32,447 $112,608 n/a
OK0668 # 12 Y:2003 12 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $16,404 $34,425 n/a
OK0668 # 13 Y:2003 13 2003 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $38,034 $1,647 Implemented
SF0266 # 01 Y:2003 01 2003 INSTALL OCCUPANCY SENSORS $1,280 $960 Not Implemented
SF0266 # 02 Y:2003 02 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,484 $1,369 Not Implemented
SF0266 # 03 Y:2003 03 2003 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,765 $2,200 Not Implemented
SF0266 # 04 Y:2003 04 2003 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $4,660 $7,712 Not Implemented
SF0266 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,906 $260 Not Implemented
SF0266 # 06 Y:2003 06 2003 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,400 $24,250 Not Implemented
SF0266 # 07 Y:2003 07 2003 INCREASE USE OF AUTOMATION $179,712 $500,000 Not Implemented
WV0276 # 07 Y:2003 07 2003 REPAIR OR REPLACE STEAM TRAPS $2,328 $480 Implemented
WV0276 # 01 Y:2003 01 2003 INSTALL WASTE HEAT BOILER TO PRODUCE STEAM $41,760 $60,000 Implemented
WV0276 # 02 Y:2003 02 2003 INSTALL TIMERS AND/OR THERMOSTATS $33,509 $580 Implemented
WV0276 # 03 Y:2003 03 2003 DIRECT WARMEST AIR TO COMBUSTION INTAKE $30,964 $9,195 Not Implemented
WV0276 # 04 Y:2003 04 2003 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $8,969 $500 Not Implemented
WV0276 # 05 Y:2003 05 2003 USE OPTIMUM THICKNESS INSULATION $8,395 $2,640 Implemented
WV0276 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,737 $16,926 Implemented
WV0276 # 08 Y:2003 08 2003 INSTALL OCCUPANCY SENSORS $2,514 $2,200 Implemented
WV0276 # 09 Y:2003 09 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,770 $80 Implemented