Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,756

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0279 # 01 Y:1996 01 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,604 $0 Implemented
OR0279 # 02 Y:1996 02 1996 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $661 $0 Not Implemented
OR0279 # 03 Y:1996 03 1996 ELIMINATE LEAKS IN WATER LINES AND VALVES $4,754 $750 Implemented
OR0279 # 04 Y:1996 04 1996 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $272 $242 Not Implemented
OR0279 # 05 Y:1996 05 1996 KEEP BOILER TUBES CLEAN $1,349 $1,500 Implemented
OR0279 # 06 Y:1996 06 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $264 $738 Not Implemented
OR0277 # 01 Y:1996 01 1996 USE OPTIMUM THICKNESS INSULATION $12,794 $20,784 Not Implemented
OR0277 # 02 Y:1996 02 1996 USE OTHER WASTE CONCENTRATION METHODS $5,324 $10,000 Implemented
OR0277 # 03 Y:1996 03 1996 UPGRADE CONTROLS ON COMPRESSORS $952 $3,840 Implemented
OR0277 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $927 $4,907 Implemented
OR0272 # 01 Y:1996 01 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $11,768 $11,600 Not Implemented
OR0272 # 02 Y:1996 02 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $247,053 $1,000,000 Implemented
OR0272 # 03 Y:1996 03 1996 KEEP BOILER TUBES CLEAN $1,014 $1,000 Not Implemented
OR0272 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $923 $2,220 Implemented
OR0272 # 05 Y:1996 05 1996 INSTALL SET-BACK TIMERS $11,080 $105,000 Not Implemented
OR0273 # 01 Y:1996 01 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,150 $6,000 Not Implemented
OR0273 # 02 Y:1996 02 1996 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $1,544 $1,000 Implemented
OR0273 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $803 $1,775 Implemented
OR0273 # 04 Y:1996 04 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $947 $5,575 Not Implemented
OR0273 # 05 Y:1996 05 1996 USE OTHER WASTE CONCENTRATION METHODS $45,735 $67,500 Not Implemented
OR0271 # 01 Y:1996 01 1996 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $9,100 $0 Not Implemented
OR0271 # 02 Y:1996 02 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,000 $5,000 Implemented
OR0271 # 03 Y:1996 03 1996 REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS $10,070 $6,000 Not Implemented
OR0271 # 04 Y:1996 04 1996 KEEP BOILER TUBES CLEAN $330 $500 Not Implemented
OR0271 # 05 Y:1996 05 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,740 $16,120 Implemented