Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,874
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CM1003 # 02 Y:2022 | 02 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $11,084 | $182,500 | Not Implemented |
CM1003 # 03 Y:2022 | 03 | 2022 | USE PHOTOCELL CONTROLS | $780 | $370 | Not Implemented |
CM1003 # 04 Y:2022 | 04 | 2022 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $227 | $0 | Not Implemented |
CM1003 # 05 Y:2022 | 05 | 2022 | INSTALL SUB-METERING EQUIPMENT | $21,570 | $3,250 | Not Implemented |
CM1003 # 06 Y:2022 | 06 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,296 | $38,900 | Not Implemented |
CO0744 # 01 Y:2022 | 01 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $26,159 | $136,687 | n/a |
CO0744 # 02 Y:2022 | 02 | 2022 | RECOVER WASTE HEAT FROM EQUIPMENT | $881 | $2,407 | n/a |
CO0744 # 03 Y:2022 | 03 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,175 | $7,076 | n/a |
CO0744 # 04 Y:2022 | 04 | 2022 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,847 | $9,768 | n/a |
CO0744 # 05 Y:2022 | 05 | 2022 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $210,000 | $58,000 | n/a |
CO0744 # 06 Y:2022 | 06 | 2022 | CONSIDER POWER LOSS AS WELL AS INITIAL LOADS AND LOAD GROWTH IN DOWN-SIZING TRANSFORMERS | $60,192 | $4,219 | n/a |
CO0744 # 07 Y:2022 | 07 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,731 | $3,276 | n/a |
CM1004 # 01 Y:2022 | 01 | 2022 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $21,300 | $72,000 | Implemented |
CM1004 # 02 Y:2022 | 02 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $20,500 | $500,000 | Not Implemented |
CM1004 # 03 Y:2022 | 03 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,490 | $4,850 | Not Implemented |
CM1004 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,250 | $11,350 | Not Implemented |
CM1004 # 05 Y:2022 | 05 | 2022 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $10,340 | $57,600 | Implemented |
CM1004 # 06 Y:2022 | 06 | 2022 | USE BATTERY STORAGE FOR DEMAND CONTROL | $36,190 | $195,000 | Not Implemented |
CM1004 # 07 Y:2022 | 07 | 2022 | APPLY FOR INVESTMENT INCENTIVES | $17,220 | $8,000 | Not Implemented |
CM1002 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,003 | $44,000 | Implemented |
CM1002 # 02 Y:2022 | 02 | 2022 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $1,800 | $100,000 | Not Implemented |
CM1002 # 03 Y:2022 | 03 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $410 | $4,100 | Not Implemented |
CM1002 # 04 Y:2022 | 04 | 2022 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,300 | $3,000 | Not Implemented |
CM1002 # 05 Y:2022 | 05 | 2022 | REDUCE VENTILATION AIR | $21,000 | $740,000 | Implemented |
CM1002 # 06 Y:2022 | 06 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $32,600 | $850,000 | Not Implemented |