Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
318
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0605 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,140 | $5,070 | Not Implemented |
CO0605 # 05 Y:2007 | 05 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,040 | $7,200 | Not Implemented |
CO0605 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $430 | $2,030 | Not Implemented |
CO0604 # 01 Y:2007 | 01 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $140,220 | $500,000 | Not Implemented |
CO0604 # 02 Y:2007 | 02 | 2007 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $112,000 | $18,430 | Not Implemented |
CO0604 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $27,400 | $2,500 | Implemented |
CO0604 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,820 | $310 | Implemented |
CO0604 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,080 | $68,340 | Not Implemented |
CO0603 # 01 Y:2007 | 01 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $996,440 | $366,170 | Not Implemented |
CO0603 # 02 Y:2007 | 02 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $121,430 | $100,000 | Not Implemented |
CO0603 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31,750 | $71,440 | Implemented |
CO0603 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,160 | $90 | Not Implemented |
CO0591 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,430 | $200 | Implemented |
CO0591 # 02 Y:2006 | 02 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $610 | $0 | Implemented |
CO0591 # 03 Y:2006 | 03 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $260 | $30 | Not Implemented |
CO0591 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,680 | $5,290 | Not Implemented |
CO0591 # 05 Y:2006 | 05 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $3,900 | $32,600 | Not Implemented |
CO0591 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $1,350 | $1,290 | Not Implemented |
CO0591 # 07 Y:2006 | 07 | 2006 | DISCONNECT BALLASTS | $310 | $110 | Implemented |
CO0590 # 01 Y:2006 | 01 | 2006 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $4,450 | $770 | Not Implemented |
CO0590 # 02 Y:2006 | 02 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,900 | $1,320 | Not Implemented |
CO0590 # 03 Y:2006 | 03 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,660 | $100 | Implemented |
CO0590 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $560 | $658 | Implemented |
CO0590 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,880 | $0 | Not Implemented |
CO0590 # 06 Y:2006 | 06 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $670 | $1,390 | Not Implemented |