Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0174 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $550 | $0 | Not Implemented |
UL0174 # 06 Y:1996 | 06 | 1996 | RECYCLE CLEANING SOLVENT AND REUSE | $6,760 | $9,845 | Implemented |
UL0174 # 07 Y:1996 | 07 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $7,302 | $2,536 | Not Implemented |
NC0097 # 09 Y:1996 | 09 | 1996 | EXPAND OPERATIONS INTO UNUSED SPACE | $13,475 | $0 | Not Implemented |
NC0097 # 08 Y:1996 | 08 | 1996 | INSTALL SYSTEM TO COLLECT SCRAP | $20,250 | $1,000 | Not Implemented |
NC0097 # 07 Y:1996 | 07 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $657 | $100 | Not Implemented |
NC0097 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $488 | $210 | Not Implemented |
NC0097 # 05 Y:1996 | 05 | 1996 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,779 | $11,650 | Not Implemented |
NC0097 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $486 | $245 | Not Implemented |
NC0097 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $469 | $772 | Not Implemented |
NC0097 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $138 | $700 | Not Implemented |
NC0097 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,021 | $2,451 | Not Implemented |
NV0074 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $385 | $225 | Implemented |
NV0074 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $864 | $200 | Implemented |
NV0074 # 03 Y:1996 | 03 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,822 | $0 | Not Implemented |
NV0074 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,545 | $200 | Implemented |
NV0074 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $387 | $200 | Implemented |
NV0074 # 06 Y:1996 | 06 | 1996 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $12,900 | $3,600 | Not Implemented |
NV0074 # 07 Y:1996 | 07 | 1996 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $4,531 | $7,000 | Not Implemented |
GT0605 # 01 Y:1996 | 01 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $18,246 | $675 | Implemented |
GT0605 # 02 Y:1996 | 02 | 1996 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,110 | $3,500 | Implemented |
GT0605 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $3,308 | $103 | Implemented |
GT0605 # 04 Y:1996 | 04 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,090 | $1,450 | Implemented |
GT0605 # 05 Y:1996 | 05 | 1996 | METER WASTE WATER | $14,720 | $0 | Implemented |
GT0605 # 06 Y:1996 | 06 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,120 | $4,300 | Implemented |