Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,260
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0012 # 03 Y:2007 | 03 | 2007 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $1,063,171 | $5,532,000 | Not Implemented |
UA0012 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,620 | $9,817 | Not Implemented |
UA0012 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $737 | $7,504 | Not Implemented |
UA0012 # 06 Y:2007 | 06 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,429 | $1,230 | Not Implemented |
OK0754 # 01 Y:2007 | 01 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,500 | $0 | Not Implemented |
OK0754 # 02 Y:2007 | 02 | 2007 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $13,115 | $1,600 | Not Implemented |
OK0754 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,872 | $1,000 | Not Implemented |
OK0754 # 04 Y:2007 | 04 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,351 | $4,638 | Implemented |
OK0754 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,311 | $814 | Implemented |
OK0754 # 06 Y:2007 | 06 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,226 | $113,794 | Not Implemented |
OK0754 # 07 Y:2007 | 07 | 2007 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $32,400 | $320 | Implemented |
OK0754 # 08 Y:2007 | 08 | 2007 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $660 | $5,303 | Not Implemented |
OK0754 # 09 Y:2007 | 09 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $8,086 | $0 | Implemented |
OK0753 # 01 Y:2007 | 01 | 2007 | OPTIMIZE PLANT POWER FACTOR | $49,649 | $0 | Implemented |
OK0753 # 02 Y:2007 | 02 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,594 | $289 | Not Implemented |
OK0753 # 03 Y:2007 | 03 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,786 | $3,600 | Not Implemented |
OK0753 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $4,874 | $9,950 | Not Implemented |
OK0753 # 05 Y:2007 | 05 | 2007 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $387,006 | $553,000 | Not Implemented |
OK0753 # 06 Y:2007 | 06 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,715 | $4,795 | Not Implemented |
OK0753 # 07 Y:2007 | 07 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,437 | $13,500 | Not Implemented |
OK0753 # 08 Y:2007 | 08 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,000 | $0 | Not Implemented |
OK0753 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,439 | $4,489 | Not Implemented |
OR0526 # 01 Y:2007 | 01 | 2007 | INSTALL SENSORS TO DETECT DEFECTS | $371,000 | $1,113,000 | Not Implemented |
OR0526 # 02 Y:2007 | 02 | 2007 | MODIFY WORKLOAD | $162,000 | $23,000 | Not Implemented |
OR0526 # 03 Y:2007 | 03 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $70,000 | $48,000 | Not Implemented |