IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,616

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA3009 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $592 $623 Implemented
UA3009 # 04 Y:2011 04 2011 INSTALL TIMERS AND/OR THERMOSTATS $51,741 $7,700 Not Implemented
UA3009 # 05 Y:2011 05 2011 USE RADIANT HEATER FOR SPOT HEATING $2,427 $3,004 Not Implemented
UA3009 # 06 Y:2011 06 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $8,000 $800 Not Implemented
UA3009 # 07 Y:2011 07 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,274 $5,000 Implemented
UA3009 # 08 Y:2011 08 2011 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $22,812 $64,000 Not Implemented
UA3009 # 09 Y:2011 09 2011 INSULATE BARE EQUIPMENT $7,844 $1,950 Not Implemented
UA3009 # 10 Y:2011 10 2011 METER WASTE WATER $55,751 $7,500 n/a
UA3008 # 01 Y:2010 01 2010 REPAIR AND ELIMINATE STEAM LEAKS $6,109 $337 Implemented
UA3008 # 02 Y:2010 02 2010 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $5,598 $17,500 Implemented
UA3008 # 03 Y:2010 03 2010 INSTALL / REPAIR INSULATION ON STEAM LINES $3,470 $2,149 Implemented
UA3008 # 04 Y:2010 04 2010 USE RADIANT HEATER FOR SPOT HEATING $12,090 $20,526 Not Implemented
UA3008 # 05 Y:2010 05 2010 INSTALL TIMERS AND/OR THERMOSTATS $497 $340 Not Implemented
UA3008 # 06 Y:2010 06 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,485 $640 Not Implemented
UA3008 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,619 $1,500 Not Implemented
UA3008 # 08 Y:2010 08 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,004 $16,161 Not Implemented
UA3007 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $45,702 $105,000 Not Implemented
UA3007 # 02 Y:2010 02 2010 INSULATE BARE EQUIPMENT $4,977 $2,445 Implemented
UA3007 # 03 Y:2010 03 2010 REPAIR AND ELIMINATE STEAM LEAKS $4,643 $3,840 Not Implemented
UA3007 # 04 Y:2010 04 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $91,320 $84,320 Not Implemented
UA3007 # 05 Y:2010 05 2010 USE OPTIMUM THICKNESS INSULATION $6,726 $6,485 Not Implemented
UA3006 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,330 $5,324 Implemented
UA3006 # 02 Y:2010 02 2010 USE PHOTOCELL CONTROLS $197 $112 Not Implemented
UA3006 # 03 Y:2010 03 2010 INSTALL TIMERS AND/OR THERMOSTATS $773 $170 Implemented
UA3006 # 04 Y:2010 04 2010 INSTALL TIMERS AND/OR THERMOSTATS $316 $50 Implemented