Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,640

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0631 # 13 Y:2001 13 2001 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $421 $688 Implemented
SD0284 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $35,467 $2,580 Implemented
SD0284 # 02 Y:2001 02 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,645 $20,000 Implemented
SD0284 # 03 Y:2001 03 2001 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $8,020 $4,000 Not Implemented
SD0284 # 04 Y:2001 04 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $14,223 $30,000 Not Implemented
SD0284 # 05 Y:2001 05 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,771 $0 Not Implemented
SD0284 # 06 Y:2001 06 2001 UPGRADE CONTROLS ON COMPRESSORS $23,814 $1,000 Implemented
SD0284 # 07 Y:2001 07 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $6,639 $240 Not Implemented
SD0284 # 08 Y:2001 08 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $30,429 $0 Implemented
SD0284 # 09 Y:2001 09 2001 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $7,125 $2,000 Implemented
SD0284 # 10 Y:2001 10 2001 SCHEDULE DELIVERIES ACCORDING TO DEMAND $69,350 $25,000 Implemented
SD0284 # 11 Y:2001 11 2001 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $71,880 $4,000 Not Implemented
SD0284 # 12 Y:2001 12 2001 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $27,940 $70,000 n/a
SD0284 # 13 Y:2001 13 2001 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $28,080 $7,000 Not Implemented
SF0223 # 01 Y:2001 01 2001 TURN OFF EQUIPMENT WHEN NOT IN USE $16,905 $0 Implemented
SF0223 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,094 $0 Not Implemented
SF0223 # 03 Y:2001 03 2001 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $29,535 $3,134 Not Implemented
SF0223 # 04 Y:2001 04 2001 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $4,914 $2,160 Implemented
SF0223 # 05 Y:2001 05 2001 INSTALL OCCUPANCY SENSORS $1,304 $1,080 Implemented
SF0223 # 06 Y:2001 06 2001 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $885 $900 Implemented
SF0223 # 07 Y:2001 07 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,122 $3,134 Implemented
SF0223 # 08 Y:2001 08 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,501 $9,123 Not Implemented
SF0223 # 09 Y:2001 09 2001 INSTALL OCCUPANCY SENSORS $343 $750 Not Implemented
SF0223 # 10 Y:2001 10 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,230 $2,999 Not Implemented
SF0223 # 11 Y:2001 11 2001 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $7,473,507 $413,000 Not Implemented