Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,640

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0190 # 04 Y:2001 04 2001 INSULATE BARE EQUIPMENT $436 $488 n/a
MS0190 # 05 Y:2001 05 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,525 $5,299 n/a
MS0190 # 06 Y:2001 06 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,862 $55,237 n/a
MS0190 # 07 Y:2001 07 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $17,869 $96,000 n/a
MS0190 # 08 Y:2001 08 2001 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $8,738 $2,250 n/a
UU0009 # 01 Y:2001 01 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $12,515 $19,380 Implemented
UU0009 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,476 $18,287 Implemented
UU0009 # 03 Y:2001 03 2001 RECOVER WASTE HEAT FROM EQUIPMENT $3,538 $1,000 Implemented
UU0009 # 04 Y:2001 04 2001 RECOVER WASTE HEAT FROM EQUIPMENT $560 $650 Implemented
UU0009 # 05 Y:2001 05 2001 USE SYNTHETIC LUBRICANT $1,276 $600 Implemented
WV0222 # 01 Y:2001 01 2001 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $16,581 $2,904 Not Implemented
WV0222 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $935 $100 Implemented
WV0222 # 03 Y:2001 03 2001 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,296 $1,000 Implemented
WV0222 # 04 Y:2001 04 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,685 $880 Implemented
WV0222 # 05 Y:2001 05 2001 INSTALL SPECTRAL REFLECTORS / DELAMP $1,036 $1,025 Not Implemented
WV0222 # 06 Y:2001 06 2001 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $13,220 $1,792 Implemented
WV0222 # 07 Y:2001 07 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,470 $208 Not Implemented
WV0222 # 08 Y:2001 08 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,491 $44 Implemented
WV0222 # 09 Y:2001 09 2001 BURN WASTE OIL FOR HEAT $2,857 $3,172 Not Implemented
WV0222 # 10 Y:2001 10 2001 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,376 $1,528 Not Implemented
WV0222 # 11 Y:2001 11 2001 RECYCLE FLUORESCENT LAMPS $3,390 $352 Implemented
WV0222 # 12 Y:2001 12 2001 $45,760 $5,000 Implemented
WV0222 # 13 Y:2001 13 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $15,000 $332 Implemented
LE0118 # 01 Y:2001 01 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,581 $2,500 Not Implemented
LE0118 # 02 Y:2001 02 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,252 $0 Not Implemented