Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
163,726
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0213 # 03 Y:1987 | 03 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,542 | $510 | Not Implemented |
OK0213 # 04 Y:1987 | 04 | 1987 | USE RADIANT HEATER FOR SPOT HEATING | $817 | $3,200 | Implemented |
GT0306 # 01 Y:1987 | 01 | 1987 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $23,465 | $0 | Implemented |
GT0306 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $565 | $300 | Implemented |
GT0306 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,954 | $20,000 | Not Implemented |
GT0306 # 04 Y:1987 | 04 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $187 | $102 | Not Implemented |
GT0306 # 05 Y:1987 | 05 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $563 | $778 | Not Implemented |
GT0307 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $775 | $300 | Implemented |
GT0307 # 02 Y:1987 | 02 | 1987 | IMPROVE LUBRICATION PRACTICES | $17,890 | $0 | Implemented |
GT0307 # 03 Y:1987 | 03 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,669 | $7,000 | Implemented |
GT0307 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,327 | $12,600 | Implemented |
GT0307 # 05 Y:1987 | 05 | 1987 | KEEP LAMPS AND REFLECTORS CLEAN | $57,046 | $102,000 | Not Implemented |
GT0307 # 06 Y:1987 | 06 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,381 | $600 | Implemented |
GT0307 # 07 Y:1987 | 07 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,314 | $2,805 | Not Implemented |
GT0307 # 08 Y:1987 | 08 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,742 | $37,500 | Implemented |
UD0223 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,084 | $0 | Implemented |
UD0223 # 02 Y:1987 | 02 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,302 | $131 | Implemented |
UD0223 # 03 Y:1987 | 03 | 1987 | INSTALL SET-BACK TIMERS | $809 | $100 | Implemented |
UD0224 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,584 | $0 | Not Implemented |
UD0224 # 02 Y:1987 | 02 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,048 | $7,200 | Not Implemented |
UD0224 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,509 | $6,000 | Not Implemented |
UD0224 # 04 Y:1987 | 04 | 1987 | REDUCE GLAZED AREAS IN BUILDINGS | $3,429 | $5,800 | Not Implemented |
UD0224 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,313 | $2,500 | Implemented |
UD0225 # 01 Y:1987 | 01 | 1987 | OPTIMIZE PLANT POWER FACTOR | $2,781 | $2,200 | Implemented |
UD0225 # 02 Y:1987 | 02 | 1987 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,298 | $1,000 | Implemented |