Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,636
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0174 # 02 Y:2000 | 02 | 2000 | USE PHOTOCELL CONTROLS | $243 | $148 | Not Implemented |
MS0174 # 03 Y:2000 | 03 | 2000 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $159 | $60 | Not Implemented |
MS0174 # 04 Y:2000 | 04 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,584 | $3,339 | Not Implemented |
MS0174 # 05 Y:2000 | 05 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,750 | $68,250 | Not Implemented |
MS0174 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $368 | $156 | Not Implemented |
MS0174 # 07 Y:2000 | 07 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $211 | $0 | Not Implemented |
MS0176 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,770 | $20,746 | Not Implemented |
MS0176 # 02 Y:2001 | 02 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,454 | $9,024 | Not Implemented |
MS0176 # 03 Y:2001 | 03 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,687 | $6,580 | Not Implemented |
MS0176 # 04 Y:2001 | 04 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $633 | $888 | Implemented |
MS0176 # 05 Y:2001 | 05 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $292 | $591 | Not Implemented |
MS0176 # 06 Y:2001 | 06 | 2001 | OPTIMIZE PLANT POWER FACTOR | $12,504 | $18,000 | Implemented |
MS0176 # 07 Y:2001 | 07 | 2001 | BURN WASTE OIL FOR HEAT | $3,044 | $3,074 | Not Implemented |
MS0176 # 08 Y:2001 | 08 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $9,033 | $25 | Implemented |
MS0178 # 01 Y:2001 | 01 | 2001 | AIR CONDITION ONLY SPACE NECESSARY | $133,472 | $38,250 | Not Implemented |
MS0178 # 02 Y:2001 | 02 | 2001 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $23,451 | $3,230 | Not Implemented |
MS0178 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $8,374 | $3,053 | Not Implemented |
MS0178 # 04 Y:2001 | 04 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,493 | $1,893 | Implemented |
MS0178 # 05 Y:2001 | 05 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $964 | $1,459 | Not Implemented |
MS0178 # 06 Y:2001 | 06 | 2001 | EXPAND OPERATIONS INTO UNUSED SPACE | $583,296 | $1,050,000 | Not Implemented |
MS0178 # 07 Y:2001 | 07 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $122,949 | $105,000 | Implemented |
MS0173 # 01 Y:2000 | 01 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,872 | $1,710 | Not Implemented |
MS0173 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,747 | $191 | Implemented |
MS0173 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $2,618 | Not Implemented |
MS0173 # 04 Y:2000 | 04 | 2000 | USE PHOTOCELL CONTROLS | $240 | $222 | Not Implemented |