IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,032

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0454 # 01 Y:1995 01 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,534 $180 Implemented
OK0454 # 02 Y:1995 02 1995 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $23,979 $0 Implemented
OK0454 # 03 Y:1995 03 1995 INSTALL SET-BACK TIMERS $767 $1,663 Not Implemented
OK0454 # 04 Y:1995 04 1995 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $2,628 $351 Not Implemented
OK0454 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $3,811 $1,996 Implemented
OK0454 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,468 $16,443 Implemented
OK0454 # 07 Y:1995 07 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $8,701 $14,986 Implemented
KU0451 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,483 $13,216 Implemented
KU0451 # 02 Y:1995 02 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $8,072 $918 Implemented
KU0451 # 03 Y:1995 03 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,560 $300 Implemented
KU0451 # 04 Y:1995 04 1995 METER WASTE WATER $11,589 $5,000 Not Implemented
KU0451 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,568 $3,155 Implemented
KU0451 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,217 $2,780 Implemented
KU0451 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $880 $650 Not Implemented
KU0451 # 08 Y:1995 08 1995 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $491 $90 Not Implemented
KU0451 # 09 Y:1995 09 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $176 $240 Implemented
KU0450 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,232 $34,320 Not Implemented
KU0450 # 02 Y:1995 02 1995 USE PHOTOCELL CONTROLS $3,753 $420 Not Implemented
KU0450 # 03 Y:1995 03 1995 INSTALL OCCUPANCY SENSORS $1,214 $1,970 Not Implemented
KU0450 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $391 $660 Not Implemented
KU0450 # 05 Y:1995 05 1995 METER WASTE WATER $2,463 $500 Not Implemented
KU0450 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,821 $232 Not Implemented
KU0450 # 07 Y:1995 07 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,310 $180 Implemented
KU0450 # 08 Y:1995 08 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,246 $165 Implemented
KU0450 # 09 Y:1995 09 1995 INSULATE BARE EQUIPMENT $1,004 $2,184 Not Implemented