Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,640
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0278 # 04 Y:2001 | 04 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $56,760 | $143,877 | Implemented |
UF0278 # 05 Y:2001 | 05 | 2001 | OPTIMIZE PLANT POWER FACTOR | $19,545 | $36,000 | Not Implemented |
UF0278 # 06 Y:2001 | 06 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $26,575 | $46,800 | Not Implemented |
UF0278 # 07 Y:2001 | 07 | 2001 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $191,133 | $282,000 | Not Implemented |
UF0278 # 08 Y:2001 | 08 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,102 | $20,000 | Not Implemented |
UF0278 # 09 Y:2001 | 09 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $682 | $1,895 | Not Implemented |
UF0278 # 10 Y:2001 | 10 | 2001 | $111,602 | $1,600 | Not Implemented | |
WV0221 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,200 | $3,420 | Implemented |
WV0221 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $394 | $60 | Implemented |
WV0221 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $8,016 | $866 | Implemented |
WV0221 # 04 Y:2001 | 04 | 2001 | OPTIMIZE PLANT POWER FACTOR | $11,836 | $8,422 | Implemented |
WV0221 # 05 Y:2001 | 05 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $12,579 | $1,200 | Implemented |
WV0221 # 06 Y:2001 | 06 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,330 | $3,980 | Implemented |
WV0221 # 07 Y:2001 | 07 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $14,790 | $1,000 | Implemented |
WV0221 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,986 | $600 | Implemented |
WV0221 # 09 Y:2001 | 09 | 2001 | RECYCLE FLUORESCENT LAMPS | $3,048 | $320 | Not Implemented |
WV0221 # 10 Y:2001 | 10 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $11,038 | $2,000 | Implemented |
WV0221 # 11 Y:2001 | 11 | 2001 | $15,000 | $6,000 | Not Implemented | |
LE0117 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,452 | $2,500 | Implemented |
LE0117 # 02 Y:2001 | 02 | 2001 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $1,140 | $300 | Implemented |
LE0117 # 03 Y:2001 | 03 | 2001 | IMPROVE LUBRICATION PRACTICES | $221 | $100 | Implemented |
LE0117 # 04 Y:2001 | 04 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $644 | $1,300 | Implemented |
LE0117 # 05 Y:2001 | 05 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,335 | $1,700 | Not Implemented |
IA0275 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,809 | $382 | Implemented |
IA0275 # 02 Y:2001 | 02 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,219 | $1,450 | Not Implemented |