Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,304
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0451 # 03 Y:2010 | 03 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,659 | $140 | Implemented |
IA0451 # 04 Y:2010 | 04 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $3,433 | $500 | Implemented |
IA0451 # 05 Y:2010 | 05 | 2010 | REDUCE VENTILATION AIR | $1,483 | $2,000 | Implemented |
IA0451 # 06 Y:2010 | 06 | 2010 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $11,080 | $240,000 | Not Implemented |
TT0055 # 01 Y:2010 | 01 | 2010 | REDUCE VENTILATION AIR | $5,009 | $17,120 | Not Implemented |
TT0055 # 02 Y:2010 | 02 | 2010 | OPTIMIZE PLANT POWER FACTOR | $11,430 | $13,000 | Implemented |
TT0055 # 03 Y:2010 | 03 | 2010 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $560 | $825 | Implemented |
TT0055 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,500 | $632 | Not Implemented |
TT0055 # 05 Y:2010 | 05 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $520 | $15 | Implemented |
TT0055 # 06 Y:2010 | 06 | 2010 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $253 | $250 | Implemented |
TT0055 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,024 | $40 | Implemented |
AM0581 # 01 Y:2010 | 01 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,089 | $51,900 | Not Implemented |
IC0172 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $115 | $0 | Implemented |
IC0172 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,201 | $0 | Not Implemented |
IC0172 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $1,944 | $360 | Not Implemented |
IC0172 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $562 | $0 | Not Implemented |
IC0172 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,411 | $940 | Not Implemented |
IC0172 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $613 | $1,248 | Not Implemented |
IC0172 # 07 Y:2010 | 07 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,978 | $72 | Not Implemented |
IC0172 # 08 Y:2010 | 08 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,552 | $0 | Not Implemented |
IC0172 # 09 Y:2010 | 09 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,810 | $0 | Not Implemented |
IC0172 # 10 Y:2010 | 10 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $490 | $0 | Not Implemented |
IC0172 # 11 Y:2010 | 11 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,144,671 | $1,170,000 | Not Implemented |
IC0172 # 12 Y:2010 | 12 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $504 | $0 | Not Implemented |
WV0409 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,346 | $55,900 | Not Implemented |