Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,295
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0511 # 06 Y:2021 | 06 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,161 | $2,385 | Not Implemented |
AS0511 # 07 Y:2021 | 07 | 2021 | INSTALL OCCUPANCY SENSORS | $3,098 | $765 | Not Implemented |
SU0505 # 01 Y:2021 | 01 | 2021 | DISCONNECT BALLASTS | $59 | $0 | Implemented |
SU0505 # 02 Y:2021 | 02 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $194 | $0 | Implemented |
SU0505 # 03 Y:2021 | 03 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,333 | $79 | Implemented |
SU0505 # 04 Y:2021 | 04 | 2021 | ELIMINATE/REDUCE AN OPERATION | $2,215 | $2,374 | Not Implemented |
SU0505 # 05 Y:2021 | 05 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $358 | $393 | Not Implemented |
SU0505 # 06 Y:2021 | 06 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $75 | $108 | Implemented |
SU0505 # 07 Y:2021 | 07 | 2021 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,193 | $7,120 | Not Implemented |
LE0505 # 01 Y:2021 | 01 | 2021 | REPAIR OR REPLACE STEAM TRAPS | $72,824 | $26,000 | Implemented |
LE0505 # 02 Y:2021 | 02 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,651 | $10,100 | Implemented |
LE0505 # 03 Y:2021 | 03 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $39,439 | $31,000 | Implemented |
LE0505 # 04 Y:2021 | 04 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $62,020 | $55,000 | Implemented |
LE0505 # 05 Y:2021 | 05 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,327 | $20,855 | Implemented |
LE0505 # 06 Y:2021 | 06 | 2021 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $48,123 | $90,000 | Implemented |
LE0505 # 07 Y:2021 | 07 | 2021 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $51,715 | $200,000 | Not Implemented |
NC0661 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,982 | $3,360 | n/a |
NC0661 # 02 Y:2021 | 02 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,073 | $27,600 | n/a |
NC0661 # 03 Y:2021 | 03 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,376 | $4,000 | n/a |
NC0661 # 04 Y:2021 | 04 | 2021 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,158 | $2,300 | n/a |
OK1046 # 01 Y:2021 | 01 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,296 | $2,422 | Not Implemented |
OK1046 # 02 Y:2021 | 02 | 2021 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $827 | $0 | Implemented |
OK1046 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $569 | $512 | Not Implemented |
OK1046 # 04 Y:2021 | 04 | 2021 | OPTIMIZE PLANT POWER FACTOR | $2,125 | $8,240 | Not Implemented |
OK1046 # 05 Y:2021 | 05 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,027 | $38,688 | Implemented |