IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,377

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0168 # 01 Y:1985 01 1985 INSTALL TIMERS AND/OR THERMOSTATS $317 $200 Implemented
OK0168 # 02 Y:1985 02 1985 OPTIMIZE PLANT POWER FACTOR $3,024 $9,555 Not Implemented
OK0168 # 03 Y:1985 03 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $831 $140 Implemented
OK0168 # 04 Y:1985 04 1985 REPAIR AND ELIMINATE STEAM LEAKS $9,402 $350 Implemented
OK0168 # 05 Y:1985 05 1985 RECOVER WASTE HEAT FROM EQUIPMENT $358 $468 Implemented
OK0168 # 06 Y:1985 06 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $236 $126 Implemented
OK0168 # 07 Y:1985 07 1985 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $595 $760 Implemented
OK0168 # 08 Y:1985 08 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,254 $648 Not Implemented
OK0168 # 09 Y:1985 09 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,999 $1,400 Implemented
OK0168 # 10 Y:1985 10 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,246 $8,400 Not Implemented
OK0169 # 01 Y:1985 01 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,330 $292 Implemented
OK0169 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,030 $1,500 Implemented
OK0169 # 03 Y:1985 03 1985 INSULATE BARE EQUIPMENT $231 $842 Implemented
OK0169 # 04 Y:1985 04 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $245 $228 Implemented
OK0169 # 05 Y:1985 05 1985 INSULATE BARE EQUIPMENT $62 $120 Implemented
OK0169 # 06 Y:1985 06 1985 INSULATE BARE EQUIPMENT $4,930 $4,780 Implemented
OK0169 # 07 Y:1985 07 1985 INSTALL SET-BACK TIMERS $2,001 $222 Implemented
OK0169 # 08 Y:1985 08 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $860 $631 Implemented
OK0169 # 09 Y:1985 09 1985 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $29,355 $6,000 Not Implemented
OK0169 # 10 Y:1985 10 1985 BURN WASTE OIL FOR HEAT $2,381 $0 Not Implemented
OK0169 # 11 Y:1985 11 1985 INSTALL TIMERS AND/OR THERMOSTATS $23,457 $1,100 Implemented
OK0169 # 12 Y:1985 12 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,997 $8,550 Implemented
OK0170 # 01 Y:1985 01 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $209 $300 Not Implemented
OK0170 # 02 Y:1985 02 1985 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $29 $80 Implemented
OK0170 # 03 Y:1985 03 1985 INSULATE BARE EQUIPMENT $365 $580 Not Implemented