Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,063
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0009 # 05 Y:2012 | 05 | 2012 | CHANGE PRODUCT SPECS | $11,780 | $0 | Not Implemented |
WM0009 # 06 Y:2012 | 06 | 2012 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $12,250 | $19,000 | Not Implemented |
WM0007 # 01 Y:2012 | 01 | 2012 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $3,505 | $0 | Not Implemented |
WM0007 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,425 | $125 | Implemented |
WM0007 # 03 Y:2012 | 03 | 2012 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,646 | $0 | Not Implemented |
WM0007 # 04 Y:2012 | 04 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,789 | $250 | Not Implemented |
WM0007 # 05 Y:2012 | 05 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,041 | $200 | Not Implemented |
WM0007 # 06 Y:2012 | 06 | 2012 | INSTALL SKYLIGHTS | $34,161 | $123,125 | Not Implemented |
WM0008 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,760 | $0 | Not Implemented |
WM0008 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,834 | $0 | Not Implemented |
WM0008 # 03 Y:2012 | 03 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,802 | $0 | Not Implemented |
WM0008 # 04 Y:2012 | 04 | 2012 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $40,676 | $83,400 | Not Implemented |
WM0008 # 05 Y:2012 | 05 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,551 | $1,000 | Not Implemented |
WM0008 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,737 | $0 | Not Implemented |
WM0008 # 07 Y:2012 | 07 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $432 | $520 | Not Implemented |
WM0008 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $1,209 | $990 | Not Implemented |
WM0008 # 09 Y:2012 | 09 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $9,137 | $3,034 | Not Implemented |
WM0008 # 10 Y:2012 | 10 | 2012 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $840 | $400 | Not Implemented |
WM0003 # 01 Y:2012 | 01 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,254 | $600 | Implemented |
WM0003 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $2,091 | $0 | Not Implemented |
WM0003 # 03 Y:2012 | 03 | 2012 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,223 | $0 | Not Implemented |
WM0003 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $226 | $120 | Implemented |
WM0003 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $137 | $360 | Implemented |
WM0003 # 06 Y:2012 | 06 | 2012 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $493 | $99 | Not Implemented |
WM0003 # 07 Y:2012 | 07 | 2012 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,160 | $900 | Not Implemented |