Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0605 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,000 | $4,908 | Implemented |
GT0605 # 08 Y:1996 | 08 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,205 | $66 | Not Implemented |
GT0605 # 09 Y:1996 | 09 | 1996 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $260,000 | $49,800 | Implemented |
UD0508 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $7,200 | $60,000 | Implemented |
UD0508 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,088 | $2,314 | Implemented |
UD0508 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,041 | $8,081 | Implemented |
UD0508 # 04 Y:1996 | 04 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $31,719 | $11,000 | Implemented |
UD0508 # 05 Y:1996 | 05 | 1996 | ELIMINATE/REDUCE AN OPERATION | $9,650 | $5,000 | Not Implemented |
UD0508 # 06 Y:1996 | 06 | 1996 | ELIMINATE/REDUCE AN OPERATION | $8,523 | $0 | Implemented |
UD0508 # 07 Y:1996 | 07 | 1996 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $101,584 | $40,000 | Implemented |
UD0508 # 08 Y:1996 | 08 | 1996 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $135,600 | $222,868 | Implemented |
UD0508 # 09 Y:1996 | 09 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,158 | $2,286 | Implemented |
UD0508 # 10 Y:1996 | 10 | 1996 | RECOVER AND REUSE COOLING WATER | $5,108 | $5,000 | Implemented |
UM0075 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,113 | $1,780 | Implemented |
UM0075 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,516 | $61,663 | Not Implemented |
UM0075 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,084 | $810 | Not Implemented |
UM0075 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,091 | $450 | Implemented |
UM0075 # 05 Y:1996 | 05 | 1996 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $1,700 | $800 | Implemented |
UM0075 # 06 Y:1996 | 06 | 1996 | USE OTHER WASTE CONCENTRATION METHODS | $3,084 | $0 | Not Implemented |
NV0073 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $366 | $100 | Implemented |
NV0073 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $823 | $208 | Implemented |
NV0073 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $863 | $163 | Implemented |
NV0073 # 04 Y:1996 | 04 | 1996 | USE PHOTOCELL CONTROLS | $10,850 | $860 | Implemented |
NV0073 # 05 Y:1996 | 05 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,700 | $2,000 | Implemented |
NV0073 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $630 | $700 | Not Implemented |