Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,063
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0189 # 03 Y:2011 | 03 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $12,266 | $100,000 | Implemented |
IC0189 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,263 | $1,142 | Implemented |
IC0189 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,441 | $382 | Implemented |
IC0189 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43 | $58 | Implemented |
IC0189 # 07 Y:2011 | 07 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $294 | $0 | Not Implemented |
IC0185 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $1,075 | $200 | Not Implemented |
IC0185 # 02 Y:2011 | 02 | 2011 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $66,621 | $315,096 | n/a |
IC0185 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $604 | $1,719 | n/a |
IC0185 # 04 Y:2011 | 04 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $283 | $1 | n/a |
IC0185 # 05 Y:2011 | 05 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,057 | $115 | n/a |
IC0185 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $205 | $334 | n/a |
IC0185 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $260,354 | $102,100 | n/a |
IC0182 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $75 | $116 | Not Implemented |
IC0182 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,306 | $672 | Not Implemented |
IC0182 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $273 | $0 | Not Implemented |
IC0182 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,045 | $43,859 | Not Implemented |
IC0182 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,734 | $11,001 | Not Implemented |
IC0182 # 06 Y:2011 | 06 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,070 | $0 | Not Implemented |
IC0182 # 07 Y:2011 | 07 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,314 | $5,489 | Not Implemented |
IC0182 # 08 Y:2011 | 08 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $950 | $311 | Not Implemented |
IC0182 # 09 Y:2011 | 09 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,442 | $311 | Not Implemented |
IC0182 # 10 Y:2011 | 10 | 2011 | INSTALL AUTOMATIC STACK DAMPER | $5,217 | $50,324 | Not Implemented |
IC0182 # 11 Y:2011 | 11 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,294 | $921 | Not Implemented |
IC0182 # 12 Y:2011 | 12 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,314 | $1,318 | Not Implemented |
IC0182 # 13 Y:2011 | 13 | 2011 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $379 | $379 | Not Implemented |