Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0048 # 05 Y:2003 | 05 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,040 | $947 | Not Implemented |
UU0048 # 06 Y:2003 | 06 | 2003 | REPAIR OR REPLACE STEAM TRAPS | $16,294 | $5,000 | Not Implemented |
UU0048 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $480 | $0 | Not Implemented |
UU0048 # 08 Y:2003 | 08 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $493 | $518 | Not Implemented |
UU0048 # 09 Y:2003 | 09 | 2003 | RECOVER AND REUSE COOLING WATER | $9,920 | $7,907 | Not Implemented |
UU0048 # 10 Y:2003 | 10 | 2003 | REUSE / RECYCLE/ SELL RUBBER PRODUCTS | $1 | $0 | Not Implemented |
MS0231 # 01 Y:2003 | 01 | 2003 | OPTIMIZE PLANT POWER FACTOR | $89,273 | $191,565 | Implemented |
MS0231 # 02 Y:2003 | 02 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $30,273 | $4,486 | Not Implemented |
MS0231 # 03 Y:2003 | 03 | 2003 | USE SYNTHETIC LUBRICANT | $13,851 | $7,500 | Not Implemented |
MS0231 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $15,508 | $26,644 | Not Implemented |
MS0231 # 05 Y:2003 | 05 | 2003 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,811 | $11,139 | Not Implemented |
MS0231 # 06 Y:2003 | 06 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,964 | $3,200 | Not Implemented |
MS0231 # 07 Y:2003 | 07 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,254 | $8,386 | Not Implemented |
MS0231 # 08 Y:2003 | 08 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $3,584 | $3,456 | Implemented |
MS0231 # 09 Y:2003 | 09 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $995 | $2,905 | Not Implemented |
MS0231 # 10 Y:2003 | 10 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $152 | $119 | Implemented |
MS0231 # 11 Y:2003 | 11 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $120 | $10 | Implemented |
NC0262 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,471 | $10,000 | Not Implemented |
NC0262 # 02 Y:2003 | 02 | 2003 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $33,773 | $55,000 | Not Implemented |
NC0262 # 03 Y:2003 | 03 | 2003 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $4,320 | $5,653 | Not Implemented |
NC0262 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,339 | $50 | Not Implemented |
NC0262 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,272 | $5,225 | Not Implemented |
NC0262 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,284 | $800 | Not Implemented |
TA0061 # 01 Y:2003 | 01 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $31,140 | $17,080 | Implemented |
TA0061 # 02 Y:2003 | 02 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,330 | $240 | Not Implemented |