Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,289
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0361 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,791 | $1,674 | Implemented |
NC0361 # 03 Y:2007 | 03 | 2007 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $6,894 | $19,950 | Not Implemented |
NC0361 # 04 Y:2007 | 04 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $658 | $617 | Implemented |
NC0361 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $579 | $100 | Implemented |
NC0361 # 06 Y:2007 | 06 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,849 | $1,200 | Implemented |
NC0361 # 07 Y:2007 | 07 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,150 | $1,200 | Implemented |
NC0361 # 08 Y:2007 | 08 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $452 | $500 | Implemented |
NC0361 # 09 Y:2007 | 09 | 2007 | KEEP BOILER TUBES CLEAN | $1,550 | $2,395 | Not Implemented |
NC0361 # 10 Y:2007 | 10 | 2007 | REDUCE EXCESSIVE BOILER BLOWDOWN | $553 | $0 | Not Implemented |
NC0361 # 11 Y:2007 | 11 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $376 | $1,000 | Not Implemented |
NC0356 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,291 | $30,000 | Not Implemented |
NC0356 # 02 Y:2007 | 02 | 2007 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $20,393 | $10,000 | Implemented |
NC0356 # 03 Y:2007 | 03 | 2007 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,040 | $13,725 | Not Implemented |
NC0356 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,456 | $100 | Implemented |
NC0356 # 05 Y:2007 | 05 | 2007 | USE PHOTOCELL CONTROLS | $798 | $500 | Not Implemented |
NC0357 # 01 Y:2007 | 01 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $30,234 | $78,000 | Not Implemented |
NC0357 # 02 Y:2007 | 02 | 2007 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $16,558 | $5,600 | Not Implemented |
NC0357 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $699 | $375 | Not Implemented |
NC0357 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,527 | $4,761 | Not Implemented |
NC0357 # 05 Y:2007 | 05 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $277 | $100 | Implemented |
NC0354 # 01 Y:2007 | 01 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $39,874 | $45,600 | Not Implemented |
NC0354 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $32,774 | $100,000 | Not Implemented |
NC0354 # 03 Y:2007 | 03 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $65,972 | $100,000 | Not Implemented |
NC0354 # 04 Y:2007 | 04 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $35,076 | $2,000 | Not Implemented |
NC0354 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,375 | $100 | Implemented |