Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,872
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0232 # 08 Y:1998 | 08 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $300,000 | $80,000 | Not Implemented |
AS0232 # 09 Y:1998 | 09 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $19,710 | $46,000 | Not Implemented |
IA0200 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,523 | $705 | Implemented |
IA0200 # 02 Y:1998 | 02 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,997 | $12,390 | Not Implemented |
IA0200 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,751 | $2,164 | Not Implemented |
IA0200 # 04 Y:1998 | 04 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,340 | $2,300 | Not Implemented |
IA0200 # 05 Y:1998 | 05 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,154 | $2,648 | Not Implemented |
IA0200 # 06 Y:1998 | 06 | 1998 | INSTALL OCCUPANCY SENSORS | $710 | $1,264 | Not Implemented |
IA0200 # 07 Y:1998 | 07 | 1998 | ELIMINATE/REDUCE AN OPERATION | $64,956 | $0 | Not Implemented |
IA0200 # 08 Y:1998 | 08 | 1998 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $278,349 | $25,000 | Not Implemented |
IA0200 # 09 Y:1998 | 09 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $38,310 | $11,590 | Not Implemented |
IA0200 # 10 Y:1998 | 10 | 1998 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $27,121 | $4,200 | Implemented |
CO0423 # 01 Y:1998 | 01 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $850 | $1,000 | Not Implemented |
CO0423 # 02 Y:1998 | 02 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $140 | $420 | Implemented |
CO0423 # 03 Y:1998 | 03 | 1998 | MINIMIZE WATER USAGE | $9,100 | $11,210 | Implemented |
CO0423 # 04 Y:1998 | 04 | 1998 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $8,870 | $2,500 | Implemented |
CO0423 # 05 Y:1998 | 05 | 1998 | ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT | $4,550 | $2,000 | Implemented |
CO0423 # 06 Y:1998 | 06 | 1998 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $2,580 | $25,000 | Implemented |
CO0423 # 07 Y:1998 | 07 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,350 | $6,900 | Implemented |
KU0501 # 01 Y:1998 | 01 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $19,090 | $33,780 | Not Implemented |
KU0501 # 02 Y:1998 | 02 | 1998 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $6,130 | $6,880 | Implemented |
KU0501 # 03 Y:1998 | 03 | 1998 | IMPROVE COMBUSTION CONTROL CAPABILITY | $2,960 | $10,890 | Not Implemented |
KU0501 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $670 | $440 | Implemented |
KU0501 # 05 Y:1998 | 05 | 1998 | USE SYNTHETIC LUBRICANT | $560 | $1,760 | Implemented |
KU0501 # 06 Y:1998 | 06 | 1998 | OPTIMIZE PLANT POWER FACTOR | $480 | $1,470 | Not Implemented |