Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,043
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0475 # 01 Y:2013 | 01 | 2013 | REDUCE SCRAP PRODUCTION | $478,006 | $153,240 | Not Implemented |
SD0475 # 02 Y:2013 | 02 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $74,589 | $105,000 | Not Implemented |
SD0475 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $72,583 | $20,000 | Not Implemented |
SD0475 # 04 Y:2013 | 04 | 2013 | INSULATE BARE EQUIPMENT | $38,801 | $8,131 | Not Implemented |
SD0475 # 05 Y:2013 | 05 | 2013 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $32,247 | $22,575 | Not Implemented |
SD0475 # 06 Y:2013 | 06 | 2013 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $31,432 | $18,685 | Not Implemented |
SD0475 # 07 Y:2013 | 07 | 2013 | USE POWER DURING OFF-PEAK PERIODS | $14,075 | $28,900 | Implemented |
SD0475 # 08 Y:2013 | 08 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,799 | $24,000 | Not Implemented |
SD0475 # 09 Y:2013 | 09 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,883 | $30,800 | Implemented |
SD0475 # 10 Y:2013 | 10 | 2013 | USE PHOTOCELL CONTROLS | $3,183 | $3,515 | Implemented |
SD0475 # 11 Y:2013 | 11 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,517 | $4,185 | Not Implemented |
SD0475 # 12 Y:2013 | 12 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,418 | $1,750 | Not Implemented |
MZ0122 # 01 Y:2013 | 01 | 2013 | INSULATE BARE EQUIPMENT | $21,142 | $3,276 | Implemented |
MZ0122 # 02 Y:2013 | 02 | 2013 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $5,133 | $21,200 | Not Implemented |
MZ0122 # 03 Y:2013 | 03 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $3,627 | $1,000 | Implemented |
MZ0122 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,176 | $4,981 | Implemented |
MZ0122 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,872 | $1,308 | Implemented |
MZ0122 # 06 Y:2013 | 06 | 2013 | INSTALL OCCUPANCY SENSORS | $1,742 | $1,240 | Implemented |
MZ0122 # 07 Y:2013 | 07 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,732 | $281 | Implemented |
MZ0122 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $807 | $37 | Not Implemented |
MZ0122 # 09 Y:2013 | 09 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $576 | $500 | Implemented |
UD0884 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $9,148 | $1,000 | Implemented |
UD0884 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,605 | $19,350 | Implemented |
UD0884 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,136 | $7,000 | Implemented |
UD0884 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,400 | $19,000 | Implemented |