Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,032

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0385 # 02 Y:1992 02 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,119 $1,080 Implemented
KU0385 # 03 Y:1992 03 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $440 $30 Implemented
KU0385 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,367 $5,928 Not Implemented
KU0385 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $853 $0 Not Implemented
KU0385 # 06 Y:1992 06 1992 INSTALL TIMERS AND/OR THERMOSTATS $1,786 $2,365 Implemented
KU0386 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,084 $0 Not Implemented
KU0386 # 02 Y:1992 02 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $15,585 $25,288 Implemented
KU0386 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,093 $6,720 Implemented
KU0386 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,155 $0 Implemented
KU0386 # 05 Y:1992 05 1992 INSTALL SET-BACK TIMERS $2,455 $1,200 Implemented
KU0386 # 06 Y:1992 06 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $594 $2,083 Not Implemented
KU0386 # 07 Y:1992 07 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,617 $10,950 Not Implemented
KU0386 # 08 Y:1992 08 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,205 $7,500 Not Implemented
KU0386 # 09 Y:1992 09 1992 CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES $3,010 $13,866 Not Implemented
KU0379 # 01 Y:1992 01 1992 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $11,070 $61,560 Not Implemented
KU0379 # 02 Y:1992 02 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,467 $22,400 Implemented
KU0379 # 03 Y:1992 03 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $7,388 $45,000 Implemented
KU0379 # 04 Y:1992 04 1992 AIR CONDITION ONLY SPACE NECESSARY $6,390 $34,000 Not Implemented
KU0379 # 05 Y:1992 05 1992 RECOVER WASTE HEAT FROM EQUIPMENT $5,891 $1,000 Not Implemented
KU0379 # 06 Y:1992 06 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,760 $20,620 Not Implemented
KU0379 # 07 Y:1992 07 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $517 $150 Implemented
KU0379 # 08 Y:1992 08 1992 INSTALL SET-BACK TIMERS $1,099 $1,050 Not Implemented
KU0379 # 09 Y:1992 09 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $175 $1,471 Not Implemented
KU0379 # 10 Y:1992 10 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $162 $600 Not Implemented
KU0380 # 01 Y:1992 01 1992 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $23,557 $93,650 Not Implemented