Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,394
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0566 # 01 Y:2004 | 01 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $148,951 | $35,885 | Implemented |
MA0566 # 02 Y:2004 | 02 | 2004 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $113,441 | $191,180 | Implemented |
MA0566 # 03 Y:2004 | 03 | 2004 | USE MINIMUM STEAM OPERATING PRESSURE | $75,183 | $1,350 | Not Implemented |
MA0566 # 04 Y:2004 | 04 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $69,926 | $70,000 | Not Implemented |
MA0566 # 05 Y:2004 | 05 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $33,400 | $20,000 | Implemented |
MA0566 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,306 | $16,750 | Not Implemented |
MA0566 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $5,889 | $3,076 | Implemented |
LL0213 # 01 Y:2004 | 01 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $479,962 | $1,400,000 | Implemented |
LL0213 # 02 Y:2004 | 02 | 2004 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $55,846 | $100,000 | Not Implemented |
LL0213 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $47,454 | $108,000 | Not Implemented |
LL0213 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,231 | $4,806 | Implemented |
LL0213 # 05 Y:2004 | 05 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,028 | $1,485 | Implemented |
LL0213 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,862 | $6,160 | Implemented |
LL0213 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,051 | $2,550 | Not Implemented |
LL0213 # 08 Y:2004 | 08 | 2004 | INSULATE BARE EQUIPMENT | $1,146 | $492 | Implemented |
LL0213 # 09 Y:2004 | 09 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $67,520 | $4,000 | Implemented |
LL0207 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $34,833 | $7,488 | Implemented |
LL0207 # 03 Y:2004 | 03 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $6,837 | $12,236 | Not Implemented |
LL0207 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,171 | $225 | Not Implemented |
LL0207 # 05 Y:2004 | 05 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,149 | $1,960 | Implemented |
LL0207 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $449 | $30 | Not Implemented |
LL0207 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $701 | $525 | Not Implemented |
LL0207 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $99 | $120 | Not Implemented |
LL0207 # 09 Y:2004 | 09 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $33 | $180 | Not Implemented |
LL0207 # 10 Y:2004 | 10 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $46,500 | $3,150 | Implemented |