IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,002

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0233 # 05 Y:2012 05 2012 OPTIMIZE PLANT POWER FACTOR $10,216 $11,120 Not Implemented
MI0233 # 06 Y:2012 06 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,406 $1,060 Not Implemented
MI0233 # 07 Y:2012 07 2012 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,508 $5,069 Not Implemented
MI0233 # 08 Y:2012 08 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,430 $2,665 Implemented
MI0233 # 09 Y:2012 09 2012 INSTALL OCCUPANCY SENSORS $5,193 $800 Implemented
MI0233 # 10 Y:2012 10 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,631 $2,050 Implemented
MI0233 # 11 Y:2012 11 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,084 $80 Implemented
MI0233 # 12 Y:2012 12 2012 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $3,056 $843 Implemented
DL0098 # 01 Y:2012 01 2012 REDUCE WATER USE WITH COUNTER CURRENT RINSING $92,987 $22,000 Implemented
DL0098 # 02 Y:2012 02 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,900 $18,000 Implemented
DL0098 # 03 Y:2012 03 2012 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,100 $18,000 Implemented
DL0098 # 04 Y:2012 04 2012 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $10,500 $19,500 Implemented
DL0098 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,060 $4,880 Implemented
DL0098 # 06 Y:2012 06 2012 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $700 $500 Not Implemented
NC0473 # 01 Y:2012 01 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $58,630 $62,137 Implemented
NC0473 # 02 Y:2012 02 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,071 $40,919 Implemented
NC0473 # 03 Y:2012 03 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $582 $562 Implemented
NC0473 # 04 Y:2012 04 2012 USE PHOTOCELL CONTROLS $6,691 $3,000 Implemented
NC0473 # 05 Y:2012 05 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,417 $200 Implemented
NC0473 # 06 Y:2012 06 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $51,369 $125,000 Implemented
NC0473 # 07 Y:2012 07 2012 BURN A LESS EXPENSIVE GRADE OF FUEL $186,985 $44,020 Not Implemented
NC0473 # 08 Y:2012 08 2012 REDUCE EXCESSIVE BOILER BLOWDOWN $732 $0 Not Implemented
NC0473 # 09 Y:2012 09 2012 INCREASE AMOUNT OF CONDENSATE RETURNED $27,364 $16,000 Implemented
NC0473 # 10 Y:2012 10 2012 REPAIR OR REPLACE STEAM TRAPS $27,978 $9,000 Implemented
WM0011 # 01 Y:2012 01 2012 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $14,000 $0 Implemented