Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0168 # 08 Y:1995 | 08 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $550 | $0 | Implemented |
ME0168 # 09 Y:1995 | 09 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $411 | $400 | Not Implemented |
ME0168 # 10 Y:1995 | 10 | 1995 | CLOSE OFF UNNEEDED STEAM LINES | $12,433 | $0 | Not Implemented |
ME0168 # 11 Y:1995 | 11 | 1995 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $4,998 | $3,500 | Not Implemented |
ME0168 # 12 Y:1995 | 12 | 1995 | MINIMIZE WATER USAGE | $4,333 | $1,300 | Implemented |
ME0168 # 13 Y:1995 | 13 | 1995 | MINIMIZE WATER USAGE | $1,618 | $440 | Implemented |
MS0035 # 01 Y:1995 | 01 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $817 | $50 | Implemented |
MS0035 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $5,164 | $2,130 | Implemented |
MS0035 # 03 Y:1995 | 03 | 1995 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $11,921 | $12,146 | Not Implemented |
MS0035 # 04 Y:1995 | 04 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $678 | $20 | Not Implemented |
MS0035 # 05 Y:1995 | 05 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $2,158 | $5,000 | Not Implemented |
MS0035 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,824 | $4,949 | Not Implemented |
MS0035 # 07 Y:1995 | 07 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $18,198 | $32,850 | Not Implemented |
NC0066 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,066 | $260 | Implemented |
NC0066 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $112 | $330 | Implemented |
NC0066 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $229 | $1,120 | Implemented |
NC0066 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $487 | $330 | Implemented |
NC0066 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $188 | $198 | Not Implemented |
NC0066 # 06 Y:1995 | 06 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,500 | $0 | Not Implemented |
NC0066 # 07 Y:1995 | 07 | 1995 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,368 | $30,845 | Not Implemented |
NC0066 # 08 Y:1995 | 08 | 1995 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,705 | $1,806 | Implemented |
NC0066 # 09 Y:1995 | 09 | 1995 | INSULATE BARE EQUIPMENT | $1,888 | $500 | Not Implemented |
NC0067 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,790 | $360 | Implemented |
NC0067 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,315 | $1,122 | Implemented |
NC0067 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,692 | $919 | Implemented |