Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,175
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0224 # 04 Y:1987 | 04 | 1987 | REDUCE GLAZED AREAS IN BUILDINGS | $3,429 | $5,800 | Not Implemented |
UD0224 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,313 | $2,500 | Implemented |
UD0225 # 01 Y:1987 | 01 | 1987 | OPTIMIZE PLANT POWER FACTOR | $2,781 | $2,200 | Implemented |
UD0225 # 02 Y:1987 | 02 | 1987 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $1,298 | $1,000 | Implemented |
UD0225 # 03 Y:1987 | 03 | 1987 | INSTALL STORM WINDOWS AND DOORS | $2,611 | $2,160 | Implemented |
UD0225 # 04 Y:1987 | 04 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $228 | $360 | Implemented |
UD0225 # 05 Y:1987 | 05 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,248 | $6,000 | Implemented |
UD0225 # 06 Y:1987 | 06 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,131 | $14,688 | Implemented |
UD0226 # 01 Y:1987 | 01 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,972 | $2,565 | Implemented |
UD0226 # 02 Y:1987 | 02 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,458 | $30,000 | Not Implemented |
UD0226 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,151 | $1,232 | Implemented |
UD0226 # 04 Y:1987 | 04 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $11,040 | $24,000 | Implemented |
UD0226 # 05 Y:1987 | 05 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,236 | $0 | Not Implemented |
UD0219 # 01 Y:1987 | 01 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $32,867 | $100,000 | Not Implemented |
UD0219 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,514 | $5,825 | Implemented |
UD0219 # 03 Y:1987 | 03 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $163 | $100 | Implemented |
UD0220 # 01 Y:1987 | 01 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,276 | $0 | Implemented |
UD0220 # 02 Y:1987 | 02 | 1987 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $6,871 | $10,000 | Not Implemented |
UD0220 # 03 Y:1987 | 03 | 1987 | MINIMIZE WATER USAGE | $1,991 | $300 | Implemented |
UD0220 # 04 Y:1987 | 04 | 1987 | HEAT WATER WITH EXHAUST HEAT | $2,530 | $2,000 | Not Implemented |
UD0221 # 01 Y:1987 | 01 | 1987 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $3,915 | $20,000 | Not Implemented |
UD0221 # 02 Y:1987 | 02 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $16,515 | $0 | Implemented |
UD0221 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,218 | $0 | Implemented |
UD0221 # 04 Y:1987 | 04 | 1987 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $7,322 | $10,000 | Implemented |
UD0221 # 05 Y:1987 | 05 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $7,926 | $9,000 | Implemented |