Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0186 # 07 Y:1996 | 07 | 1996 | METER WASTE WATER | $8,798 | $5,000 | Implemented |
AS0186 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $465 | $0 | Implemented |
IA0153 # 01 Y:1996 | 01 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $8,102 | $2,678 | Implemented |
IA0153 # 02 Y:1996 | 02 | 1996 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $5,206 | $22,090 | Not Implemented |
IA0153 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,805 | $4,646 | Implemented |
IA0153 # 04 Y:1996 | 04 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,758 | $2,000 | Implemented |
IA0153 # 05 Y:1996 | 05 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,111 | $354 | Not Implemented |
IA0153 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,949 | $4,617 | Not Implemented |
IA0153 # 07 Y:1996 | 07 | 1996 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $2,570 | $250 | Implemented |
IA0153 # 08 Y:1996 | 08 | 1996 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,124 | $4,500 | Not Implemented |
IA0153 # 09 Y:1996 | 09 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,892 | $2,167 | Not Implemented |
IA0153 # 10 Y:1996 | 10 | 1996 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $659 | $659 | Not Implemented |
IA0153 # 11 Y:1996 | 11 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $243 | $250 | Implemented |
OR0271 # 01 Y:1996 | 01 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,100 | $0 | Not Implemented |
OR0271 # 02 Y:1996 | 02 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,000 | $5,000 | Implemented |
OR0271 # 03 Y:1996 | 03 | 1996 | REPLACE STEAM JETS ON VACUUM SYSTEM WITH ELECTRIC MOTOR DRIVEN VACUUM PUMPS | $10,070 | $6,000 | Not Implemented |
OR0271 # 04 Y:1996 | 04 | 1996 | KEEP BOILER TUBES CLEAN | $330 | $500 | Not Implemented |
OR0271 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,740 | $16,120 | Implemented |
OR0271 # 06 Y:1996 | 06 | 1996 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $160 | $0 | Not Implemented |
OR0271 # 07 Y:1996 | 07 | 1996 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $5,480 | $3,000 | Implemented |
OR0274 # 01 Y:1996 | 01 | 1996 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $195,168 | $0 | Implemented |
OR0274 # 02 Y:1996 | 02 | 1996 | IMPROVE COMBUSTION CONTROL CAPABILITY | $13,394 | $0 | Not Implemented |
OR0274 # 03 Y:1996 | 03 | 1996 | RECOVER MECHANICAL ENERGY | $2,710 | $0 | Not Implemented |
OR0274 # 04 Y:1996 | 04 | 1996 | HEAT WATER WITH EXHAUST HEAT | $9,179 | $27,349 | Not Implemented |
OR0274 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,737 | $2,317 | Not Implemented |