Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,875
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0301 # 02 Y:2011 | 02 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,978 | $689 | Not Implemented |
SU0301 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,477 | $2,028 | Implemented |
SU0301 # 04 Y:2011 | 04 | 2011 | RECOVER AND REUSE SPENT ACID BATHS | $1,049 | $958 | Not Implemented |
SU0301 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $377 | $487 | Not Implemented |
SU0301 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $496 | $895 | Not Implemented |
SU0301 # 07 Y:2011 | 07 | 2011 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $11,025 | $26,043 | Not Implemented |
SU0301 # 08 Y:2011 | 08 | 2011 | OPTIMIZE PLANT POWER FACTOR | $5,328 | $18,204 | Not Implemented |
SU0300 # 01 Y:2010 | 01 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $64,500 | $3,122 | Implemented |
SU0300 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,801 | $1,925 | Implemented |
SU0300 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $828 | $883 | Not Implemented |
SU0300 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $5,195 | $8,204 | Not Implemented |
SU0300 # 05 Y:2010 | 05 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $6,305 | $11,140 | Not Implemented |
SU0298 # 01 Y:2010 | 01 | 2010 | PAY BILLS ON TIME TO AVOID LATE FEES | $21,457 | $0 | Not Implemented |
SU0298 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,096 | $0 | Not Implemented |
SU0298 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,218 | $1,248 | Not Implemented |
SU0298 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $431 | $86 | Not Implemented |
SU0298 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $792 | $266 | Not Implemented |
SU0298 # 06 Y:2010 | 06 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $125 | $274 | Not Implemented |
SU0298 # 07 Y:2010 | 07 | 2010 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $35,873 | $81,798 | Not Implemented |
SU0298 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,123 | $45,613 | Not Implemented |
SU0298 # 09 Y:2010 | 09 | 2010 | OPTIMIZE PLANT POWER FACTOR | $4,349 | $17,933 | Not Implemented |
SU0297 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $30,345 | $0 | Implemented |
SU0297 # 02 Y:2010 | 02 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,367 | $0 | Not Implemented |
SU0297 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $11,458 | $697 | Implemented |
SU0297 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $1,997 | $209 | Not Implemented |