Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
318
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0552 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $47,960 | $7,780 | Not Implemented |
CO0552 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,570 | $620 | Implemented |
CO0552 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,520 | $270 | Not Implemented |
CO0552 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $834 | $560 | Implemented |
CO0552 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,500 | $3,050 | Implemented |
CO0552 # 06 Y:2004 | 06 | 2004 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $14,250 | $71,200 | Not Implemented |
CO0552 # 07 Y:2004 | 07 | 2004 | RECOVER AND REUSE COOLING WATER | $4,170 | $20,000 | Not Implemented |
CO0552 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $950 | $2,800 | Not Implemented |
CO0551 # 01 Y:2004 | 01 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,340 | $4,280 | Not Implemented |
CO0551 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,230 | $60 | Implemented |
CO0551 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $910 | $320 | Implemented |
CO0551 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $190 | $750 | Not Implemented |
CO0551 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,300 | $13,550 | Not Implemented |
CO0551 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $510 | $300 | Not Implemented |
CO0551 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $140 | $390 | Not Implemented |
CO0529 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $41,400 | $7,000 | Implemented |
CO0529 # 02 Y:2003 | 02 | 2003 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $5,520 | $5,060 | Not Implemented |
CO0529 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,790 | $16,530 | Not Implemented |
CO0529 # 04 Y:2003 | 04 | 2003 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $3,810 | $3,920 | Implemented |
CO0529 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,090 | $190 | Implemented |
CO0529 # 06 Y:2003 | 06 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,240 | $4,000 | Not Implemented |
CO0529 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $386 | $128 | Implemented |
CO0529 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $218 | $250 | Implemented |
CO0529 # 09 Y:2003 | 09 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $460 | $1,440 | Not Implemented |
CO0528 # 01 Y:2003 | 01 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $20,940 | $4,360 | Implemented |