Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,616
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0103 # 05 Y:1998 | 05 | 1998 | BURN WASTE OIL FOR HEAT | $8,596 | $5,256 | Not Implemented |
MS0103 # 06 Y:1998 | 06 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $108,775 | $0 | Implemented |
MS0101 # 01 Y:1998 | 01 | 1998 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,713 | $5,100 | Not Implemented |
MS0101 # 02 Y:1998 | 02 | 1998 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $1,593 | $4,400 | Not Implemented |
MS0101 # 03 Y:1998 | 03 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,386 | $1,000 | Implemented |
MS0101 # 04 Y:1998 | 04 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,750 | $0 | Implemented |
MS0101 # 05 Y:1998 | 05 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,012 | $816 | Not Implemented |
MS0101 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $7,360 | $420 | Implemented |
MS0101 # 07 Y:1998 | 07 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $207 | $0 | Implemented |
MS0101 # 08 Y:1998 | 08 | 1998 | COMBINE UTILITY METERS | $420 | $1,225 | Implemented |
GT0627 # 01 Y:1997 | 01 | 1997 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $26,200 | $173,400 | Implemented |
GT0627 # 02 Y:1997 | 02 | 1997 | COMBINE UTILITY METERS | $3,680 | $1,830 | Not Implemented |
GT0627 # 03 Y:1997 | 03 | 1997 | OPTIMIZE PLANT POWER FACTOR | $22,150 | $24,500 | Implemented |
GT0627 # 04 Y:1997 | 04 | 1997 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,488 | $400 | Implemented |
GT0627 # 05 Y:1997 | 05 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,290 | $13,500 | Not Implemented |
GT0627 # 06 Y:1997 | 06 | 1997 | INSULATE BARE EQUIPMENT | $1,303 | $1,665 | Implemented |
GT0627 # 07 Y:1997 | 07 | 1997 | INCREASE AMOUNT OF CONDENSATE RETURNED | $14,110 | $850 | Implemented |
GT0627 # 08 Y:1997 | 08 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,850 | $49,700 | Implemented |
GT0627 # 09 Y:1997 | 09 | 1997 | IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM | $40,430 | $4,200 | Implemented |
MS0094 # 01 Y:1997 | 01 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $674 | $498 | Implemented |
MS0094 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $668 | $2,014 | Not Implemented |
MS0094 # 03 Y:1997 | 03 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $226 | $0 | Implemented |
MS0094 # 04 Y:1997 | 04 | 1997 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $578 | $3,500 | Not Implemented |
MS0094 # 05 Y:1997 | 05 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $20,000 | $21,264 | Implemented |
MS0085 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $9,330 | $5,625 | Implemented |