Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,529
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0690 # 03 Y:2000 | 03 | 2000 | INSTALL SKYLIGHTS | $1,332 | $4,380 | n/a |
GT0690 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $499 | $0 | n/a |
GT0690 # 05 Y:2000 | 05 | 2000 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $20,979 | $900 | n/a |
GT0690 # 06 Y:2000 | 06 | 2000 | DEVELOP STANDARD OPERATING PROCEDURES | $4,500 | $20,700 | n/a |
GT0689 # 01 Y:2000 | 01 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $32,450 | $0 | n/a |
GT0689 # 02 Y:2000 | 02 | 2000 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $9,458 | $8,900 | n/a |
GT0689 # 03 Y:2000 | 03 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $72,000 | $112,000 | n/a |
GT0689 # 04 Y:2000 | 04 | 2000 | ADD ADDITIONAL PRODUCTION SHIFT | $336,000 | $225,000 | n/a |
GT0689 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,495 | $2,000 | n/a |
GT0689 # 06 Y:2000 | 06 | 2000 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $82,231 | $0 | n/a |
GT0689 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,460 | $32,400 | n/a |
GT0689 # 08 Y:2000 | 08 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $16,070 | $61,209 | n/a |
GT0689 # 09 Y:2000 | 09 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,228 | $0 | n/a |
GT0689 # 10 Y:2000 | 10 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,362 | $72,500 | n/a |
GT0688 # 01 Y:2000 | 01 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,444 | $2,240 | Implemented |
GT0688 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,360 | $15,907 | Not Implemented |
GT0688 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,190 | $12,285 | Not Implemented |
GT0688 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,760 | $1,050 | Not Implemented |
GT0688 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $280 | $800 | Implemented |
GT0688 # 06 Y:2000 | 06 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $17,022 | $53,400 | Implemented |
GT0688 # 07 Y:2000 | 07 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,920 | $450 | Not Implemented |
GT0688 # 08 Y:2000 | 08 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,435 | $4,950 | Not Implemented |
GT0687 # 01 Y:2000 | 01 | 2000 | COMBINE UTILITY METERS | $83,824 | $0 | Implemented |
GT0687 # 02 Y:2000 | 02 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $33,596 | $0 | Not Implemented |
GT0687 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $608 | $950 | Implemented |