Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,573
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0721 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,040 | $11,100 | Implemented |
UD0721 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $2,714 | $345 | Not Implemented |
UD0721 # 08 Y:2005 | 08 | 2005 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,229 | $860 | Not Implemented |
UD0721 # 09 Y:2005 | 09 | 2005 | INSULATE BARE EQUIPMENT | $675 | $1,820 | Not Implemented |
UD0721 # 10 Y:2005 | 10 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $614 | $0 | Not Implemented |
UD0721 # 11 Y:2005 | 11 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $613 | $420 | Not Implemented |
UD0721 # 12 Y:2005 | 12 | 2005 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $560 | $1,000 | Not Implemented |
UD0721 # 13 Y:2005 | 13 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $506 | $1,897 | Not Implemented |
UD0719 # 01 Y:2005 | 01 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $41,821 | $11,000 | Not Implemented |
UD0719 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $25,553 | $24,000 | Not Implemented |
UD0719 # 03 Y:2005 | 03 | 2005 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $13,165 | $20,000 | Implemented |
UD0719 # 04 Y:2005 | 04 | 2005 | OPTIMIZE PLANT POWER FACTOR | $3,580 | $4,800 | Not Implemented |
UD0719 # 05 Y:2005 | 05 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,455 | $12,060 | Implemented |
UD0719 # 06 Y:2005 | 06 | 2005 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,173 | $3,498 | Not Implemented |
UD0719 # 07 Y:2005 | 07 | 2005 | DISCONNECT BALLASTS | $1,102 | $75 | Implemented |
UD0719 # 08 Y:2005 | 08 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $583 | $0 | Not Implemented |
UD0719 # 09 Y:2005 | 09 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $583 | $20 | Implemented |
UD0719 # 10 Y:2005 | 10 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $485 | $970 | Not Implemented |
UD0719 # 11 Y:2005 | 11 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $429 | $0 | Not Implemented |
IC0101 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,241 | $2,600 | Not Implemented |
IC0101 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,006 | $0 | Not Implemented |
IC0101 # 03 Y:2005 | 03 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $362 | $994 | Not Implemented |
IC0101 # 04 Y:2005 | 04 | 2005 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,474 | $0 | Not Implemented |
IC0101 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,368 | $15,000 | Not Implemented |
IC0101 # 06 Y:2005 | 06 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,574 | $21,820 | Not Implemented |