Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,520
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0145 # 05 Y:1999 | 05 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $50,143 | $85,000 | Not Implemented |
UM0145 # 06 Y:1999 | 06 | 1999 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $24,222 | $60,000 | Implemented |
UM0145 # 07 Y:1999 | 07 | 1999 | IMPROVE SPACE COMFORT CONDITIONING | $16,869 | $14,495 | Implemented |
UM0145 # 08 Y:1999 | 08 | 1999 | INSTALL MAGAZINES FOR TEMPORARY STORAGE | $32,500 | $2,000 | Not Implemented |
DS0144 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,077 | $438 | Implemented |
DS0144 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $567 | $259 | Implemented |
DS0144 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $705 | $216 | Not Implemented |
DS0144 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,642 | $725 | Implemented |
DS0144 # 05 Y:1999 | 05 | 1999 | BURN WASTE OIL FOR HEAT | $1,318 | $1,695 | Not Implemented |
DS0144 # 06 Y:1999 | 06 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $2,225 | $1,350 | Implemented |
DS0144 # 07 Y:1999 | 07 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $286 | $0 | Implemented |
IA0222 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,656 | $1,064 | Not Implemented |
IA0222 # 02 Y:1999 | 02 | 1999 | INSTALL OCCUPANCY SENSORS | $561 | $931 | Implemented |
IA0222 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $391 | $33 | Implemented |
IA0222 # 04 Y:1999 | 04 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $421 | $226 | Implemented |
IA0222 # 05 Y:1999 | 05 | 1999 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $5,097 | $3,584 | Not Implemented |
IA0222 # 06 Y:1999 | 06 | 1999 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $3,600 | $900 | Implemented |
IA0222 # 07 Y:1999 | 07 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,900 | $3,000 | Not Implemented |
IA0222 # 08 Y:1999 | 08 | 1999 | ADD ADDITIONAL PRODUCTION SHIFT | $199,932 | $425,000 | Implemented |
IA0222 # 09 Y:1999 | 09 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $17,160 | $25,792 | Not Implemented |
IA0222 # 10 Y:1999 | 10 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $512 | $1,200 | Not Implemented |
KU0521 # 01 Y:1999 | 01 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $3,190 | $8,580 | Not Implemented |
KU0521 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $640 | $500 | Implemented |
KU0521 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $270 | Implemented |
KU0521 # 04 Y:1999 | 04 | 1999 | USE SYNTHETIC LUBRICANT | $230 | $640 | Implemented |