Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0617 # 07 Y:2001 | 07 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $23,985 | $27,632 | Not Implemented |
OK0614 # 01 Y:2001 | 01 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,325 | $335 | Not Implemented |
OK0614 # 02 Y:2001 | 02 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,500 | $6,100 | Not Implemented |
OK0614 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $5,656 | $9,700 | Implemented |
OK0614 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $377 | $3,700 | Not Implemented |
OK0614 # 05 Y:2001 | 05 | 2001 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $9,100 | $4,000 | Implemented |
OK0613 # 01 Y:2001 | 01 | 2001 | INSTALL SET-BACK TIMERS | $10,756 | $1,026 | Not Implemented |
OK0613 # 02 Y:2001 | 02 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,071 | $4,000 | Implemented |
OK0613 # 03 Y:2001 | 03 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $456 | $2,600 | Implemented |
OK0613 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,475 | $7,120 | Not Implemented |
OK0613 # 05 Y:2001 | 05 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,508 | $6,000 | Not Implemented |
OK0613 # 06 Y:2001 | 06 | 2001 | RECOVER AND REUSE WASTE MATERIAL | $54,883 | $20,680 | Not Implemented |
OK0613 # 07 Y:2001 | 07 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,400 | $572 | Not Implemented |
OK0613 # 08 Y:2001 | 08 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $304 | $125 | Not Implemented |
OK0612 # 01 Y:2001 | 01 | 2001 | INSTALL SET-BACK TIMERS | $88,000 | $17,542 | Implemented |
OK0612 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,333 | $577 | Not Implemented |
OK0612 # 03 Y:2001 | 03 | 2001 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $2,772 | $5,200 | Not Implemented |
OK0612 # 04 Y:2001 | 04 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $463 | $0 | Implemented |
OK0612 # 05 Y:2001 | 05 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $1,650 | $720 | Implemented |
OK0612 # 06 Y:2001 | 06 | 2001 | OPTIMIZE PLANT POWER FACTOR | $14,115 | $5,150 | Not Implemented |
OK0611 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $147 | $126 | Implemented |
OK0611 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,500 | $360 | Implemented |
OK0611 # 03 Y:2001 | 03 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,000 | $13,300 | Implemented |
OK0611 # 04 Y:2001 | 04 | 2001 | MODIFY WORKLOAD | $147 | $70 | Implemented |
OK0611 # 05 Y:2001 | 05 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,100 | $5,800 | Not Implemented |