Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,091
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0113 # 01 Y:1991 | 01 | 1991 | RECOVER AND REUSE COOLING WATER | $2,203 | $2,100 | Implemented |
OR0113 # 02 Y:1991 | 02 | 1991 | TREAT AND REUSE RINSE WATERS | $1,242 | $0 | Not Implemented |
OR0113 # 03 Y:1991 | 03 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $24 | $23 | Implemented |
OR0113 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $211 | $319 | Implemented |
OR0113 # 05 Y:1991 | 05 | 1991 | TREAT AND REUSE RINSE WATERS | $366 | $0 | Implemented |
OR0113 # 06 Y:1991 | 06 | 1991 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $588 | $1,500 | Implemented |
OR0113 # 07 Y:1991 | 07 | 1991 | INSULATE BARE EQUIPMENT | $55 | $234 | Implemented |
OR0113 # 08 Y:1991 | 08 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $215 | $1,000 | Implemented |
OR0114 # 01 Y:1991 | 01 | 1991 | INSTALL SET-BACK TIMERS | $1,058 | $0 | Not Implemented |
OR0114 # 02 Y:1991 | 02 | 1991 | INSTALL SET-BACK TIMERS | $486 | $0 | Not Implemented |
OR0114 # 03 Y:1991 | 03 | 1991 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $60 | $78 | Not Implemented |
OR0114 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $181 | $0 | Not Implemented |
OR0114 # 05 Y:1991 | 05 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $12,611 | $0 | Not Implemented |
OR0115 # 01 Y:1991 | 01 | 1991 | USE MINIMUM STEAM OPERATING PRESSURE | $126 | $0 | Not Implemented |
OR0115 # 02 Y:1991 | 02 | 1991 | INCREASE AMOUNT OF CONDENSATE RETURNED | $142 | $175 | Not Implemented |
OR0115 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,297 | $0 | Not Implemented |
OR0115 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $85 | $284 | Not Implemented |
OR0115 # 05 Y:1991 | 05 | 1991 | OPTIMIZE PLANT POWER FACTOR | $506 | $2,700 | Not Implemented |
RU0114 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $826 | $0 | Implemented |
RU0114 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $261 | $214 | Implemented |
RU0114 # 03 Y:1991 | 03 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,104 | $2,150 | Implemented |
RU0114 # 04 Y:1991 | 04 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $858 | $700 | Implemented |
RU0114 # 05 Y:1991 | 05 | 1991 | IMPROVE LUBRICATION PRACTICES | $2,850 | $800 | Implemented |
RU0114 # 06 Y:1991 | 06 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,509 | $500 | Implemented |
RU0114 # 07 Y:1991 | 07 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $52,380 | $15,000 | Implemented |