Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,708
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0510 # 09 Y:2002 | 09 | 2002 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $750 | $0 | Implemented |
UF0301 # 01 Y:2002 | 01 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,016 | $0 | Not Implemented |
UF0301 # 02 Y:2002 | 02 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,352 | $134 | Not Implemented |
UF0301 # 03 Y:2002 | 03 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $809 | $0 | Not Implemented |
UF0301 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,526 | $1,768 | Not Implemented |
UF0301 # 05 Y:2002 | 05 | 2002 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $51,092 | $121,957 | Not Implemented |
UF0301 # 06 Y:2002 | 06 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,517 | $16,521 | Not Implemented |
UF0301 # 07 Y:2002 | 07 | 2002 | RECOVER AND REUSE WASTE MATERIAL | $40,494 | $1,035 | Not Implemented |
UF0301 # 08 Y:2002 | 08 | 2002 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $70,176 | $0 | Not Implemented |
UF0301 # 09 Y:2002 | 09 | 2002 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $56,304 | $376 | Not Implemented |
WI0423 # 01 Y:2002 | 01 | 2002 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $14,059 | $20,000 | Not Implemented |
WI0423 # 02 Y:2002 | 02 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,458 | $500 | Implemented |
WI0423 # 03 Y:2002 | 03 | 2002 | USE EVAPORATION TO CONCENTRATE MATERIAL | $9,308 | $11,000 | Not Implemented |
WI0423 # 04 Y:2002 | 04 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,599 | $12,000 | Not Implemented |
WI0423 # 05 Y:2002 | 05 | 2002 | COVER OPEN TANKS | $3,017 | $864 | Not Implemented |
WI0423 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,966 | $5,584 | Implemented |
WI0423 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $1,365 | $2,500 | Implemented |
WI0423 # 08 Y:2002 | 08 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $359 | $369 | Implemented |
WV0240 # 01 Y:2002 | 01 | 2002 | INSTALL OCCUPANCY SENSORS | $1,256 | $450 | Implemented |
WV0240 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,302 | $26,610 | Implemented |
WV0240 # 03 Y:2002 | 03 | 2002 | INSULATE BARE EQUIPMENT | $213 | $163 | Implemented |
WV0240 # 04 Y:2002 | 04 | 2002 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $123 | $86 | Implemented |
WV0240 # 05 Y:2002 | 05 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $500 | $248 | Not Implemented |
WV0240 # 06 Y:2002 | 06 | 2002 | USE OPTIMUM THICKNESS INSULATION | $21,621 | $9,375 | Not Implemented |
WV0240 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $18,364 | $1,500 | Implemented |