IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,394

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0192 # 01 Y:2004 01 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $61,254 $2,590 Implemented
LL0192 # 02 Y:2004 02 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $55,907 $0 Not Implemented
LL0192 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $41,577 $4,400 Implemented
LL0192 # 04 Y:2004 04 2004 USE PHOTOCELL CONTROLS $21,326 $420 Not Implemented
LL0192 # 05 Y:2004 05 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $7,708 $2,585 Implemented
LL0192 # 06 Y:2004 06 2004 USE PHOTOCELL CONTROLS $3,529 $720 Not Implemented
LL0192 # 07 Y:2004 07 2004 INSULATE BARE EQUIPMENT $2,881 $911 Not Implemented
LL0192 # 08 Y:2004 08 2004 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $5,610 $6,030 Not Implemented
NC0289 # 01 Y:2004 01 2004 RECYCLE WASTE INK AND CLEANUP SOLVENT $21,873 $25,000 Implemented
NC0289 # 02 Y:2004 02 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,527 $0 Not Implemented
NC0289 # 03 Y:2004 03 2004 DEVELOP A REPAIR/REPLACE POLICY $230 $154 Not Implemented
NC0289 # 04 Y:2004 04 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $972 $1,000 Not Implemented
LE0192 # 01 Y:2004 01 2004 RECOVER WASTE HEAT FROM EQUIPMENT $22,723 $5,000 Not Implemented
LE0192 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $9,677 $0 Implemented
LE0192 # 03 Y:2004 03 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $9,668 $3,000 Not Implemented
LE0192 # 04 Y:2004 04 2004 INSTALL / REPAIR INSULATION ON STEAM LINES $7,128 $1,084 Implemented
LE0192 # 05 Y:2004 05 2004 INSULATE BARE EQUIPMENT $2,750 $8,250 Not Implemented
LE0192 # 06 Y:2004 06 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $2,219 $0 Implemented
LE0191 # 01 Y:2004 01 2004 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $19,209 $8,000 Not Implemented
LE0191 # 02 Y:2004 02 2004 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $13,043 $2,500 Implemented
LE0191 # 03 Y:2004 03 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $9,591 $3,200 Not Implemented
LE0191 # 04 Y:2004 04 2004 OPTIMIZE PLANT POWER FACTOR $8,221 $2,500 Implemented
LE0191 # 05 Y:2004 05 2004 INSTALL TIMERS AND/OR THERMOSTATS $4,530 $750 Implemented
LE0191 # 06 Y:2004 06 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,195 $0 Not Implemented
LE0191 # 07 Y:2004 07 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,161 $200 Implemented