Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,215
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0041 # 06 Y:2015 | 06 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,713 | $310 | Not Implemented |
IP0041 # 07 Y:2015 | 07 | 2015 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,476 | $340 | Not Implemented |
IP0041 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,278 | $5,296 | Implemented |
IP0041 # 09 Y:2015 | 09 | 2015 | $5,896 | $5,317 | Not Implemented | |
IP0041 # 10 Y:2015 | 10 | 2015 | OPTIMIZE PLANT POWER FACTOR | $1,104 | $5,400 | Not Implemented |
IP0041 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $113 | $385 | Implemented |
MZ0181 # 01 Y:2015 | 01 | 2015 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,643 | $4,000 | Not Implemented |
MZ0181 # 02 Y:2015 | 02 | 2015 | ELIMINATE/REDUCE AN OPERATION | $419 | $0 | Not Implemented |
MZ0181 # 03 Y:2015 | 03 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,725 | $8,000 | Not Implemented |
MZ0181 # 04 Y:2015 | 04 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,719 | $0 | Implemented |
NC0540 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,312 | $100 | Implemented |
NC0540 # 02 Y:2015 | 02 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,496 | $659 | Implemented |
NC0540 # 03 Y:2015 | 03 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $1,065 | $200 | Implemented |
NC0540 # 04 Y:2015 | 04 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,539 | $1,500 | Not Implemented |
NC0540 # 05 Y:2015 | 05 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,295 | $9,000 | Implemented |
NC0540 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,087 | $19,400 | Not Implemented |
NC0540 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $2,592 | $1,388 | Not Implemented |
NC0540 # 08 Y:2015 | 08 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $113 | $120 | Not Implemented |
NC0540 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $588 | $160 | Implemented |
NC0540 # 10 Y:2015 | 10 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $6,804 | $22,500 | Implemented |
NC0540 # 11 Y:2015 | 11 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $248 | $1,000 | Not Implemented |
NC0540 # 12 Y:2015 | 12 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,592 | $67,363 | Implemented |
AM0684 # 01 Y:2015 | 01 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $24,700 | $0 | Not Implemented |
AM0684 # 02 Y:2015 | 02 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,370 | $0 | Not Implemented |
AM0684 # 03 Y:2015 | 03 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,080 | $2,200 | Not Implemented |