Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,573
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0084 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,024 | $430,000 | Not Implemented |
IC0084 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $48,922 | $200 | Implemented |
IC0084 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $124,469 | $513 | Implemented |
IC0084 # 10 Y:2004 | 10 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $794 | $5,100 | Implemented |
IC0084 # 11 Y:2004 | 11 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $122 | $0 | Implemented |
IC0084 # 12 Y:2004 | 12 | 2004 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $156 | $1,854 | Not Implemented |
IC0084 # 13 Y:2004 | 13 | 2004 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $197 | $240 | Implemented |
IC0084 # 14 Y:2004 | 14 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,645 | $96,551 | Not Implemented |
IC0084 # 15 Y:2004 | 15 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,601 | $13,349 | Not Implemented |
IC0084 # 16 Y:2004 | 16 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,775 | $2,376 | Not Implemented |
IC0084 # 17 Y:2004 | 17 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,694 | $5,190 | Not Implemented |
IC0077 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,066 | $2,100 | Implemented |
IC0077 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,003 | $199 | Implemented |
IC0077 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,747 | $74,730 | Not Implemented |
IC0077 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $999 | $4,888 | Not Implemented |
IC0077 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,807 | $2,963 | Implemented |
IC0077 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $743 | $4,033 | Not Implemented |
BD0247 # 01 Y:2003 | 01 | 2003 | USE POWER DURING OFF-PEAK PERIODS | $43,745 | $2,000 | Not Implemented |
BD0247 # 02 Y:2003 | 02 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,627 | $1,000 | Implemented |
BD0247 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $13,156 | $8,080 | Implemented |
BD0247 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,345 | $35,510 | Implemented |
BD0247 # 05 Y:2003 | 05 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $7,407 | $8,000 | Implemented |
BD0247 # 06 Y:2003 | 06 | 2003 | USE PHOTOCELL CONTROLS | $5,082 | $1,500 | Implemented |
BD0247 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,389 | $9,225 | Implemented |
BD0247 # 08 Y:2003 | 08 | 2003 | USE SYNTHETIC LUBRICANT | $2,306 | $500 | Implemented |