Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
70
matching recommendationsNAICS | 3328 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0130 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,986 | $2,522 | Not Implemented |
UA0130 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,890 | $100 | Implemented |
UA0130 # 01 Y:2014 | 01 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $15,715 | $35,154 | Not Implemented |
UA0130 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $2,774 | $200 | Implemented |
UA0130 # 04 Y:2014 | 04 | 2014 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,266 | $0 | Implemented |
UA0130 # 02 Y:2014 | 02 | 2014 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,506 | $6,410 | Not Implemented |
UA0130 # 05 Y:2014 | 05 | 2014 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $6,867 | $4,120 | Not Implemented |
UD0913 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,485 | $5,000 | Not Implemented |
UD0913 # 11 Y:2014 | 11 | 2014 | USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS | $27,921 | $55,000 | Not Implemented |
UD0913 # 08 Y:2014 | 08 | 2014 | COVER OPEN TANKS | $3,270 | $6,780 | Implemented |
UD0913 # 10 Y:2014 | 10 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $414,555 | $27,000 | Not Implemented |
UD0913 # 06 Y:2014 | 06 | 2014 | REPLACE BOILER | $19,697 | $163,500 | Not Implemented |
UD0913 # 09 Y:2014 | 09 | 2014 | INSTALL AUTOMATIC STACK DAMPER | $2,665 | $0 | Implemented |
UD0913 # 01 Y:2014 | 01 | 2014 | UPGRADE CONVEYORS | $528 | $255 | Not Implemented |
UD0913 # 03 Y:2014 | 03 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $511 | $1,275 | Implemented |
UD0913 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,643 | $8,500 | Not Implemented |
UD0913 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $615 | $570 | Implemented |
UD0913 # 05 Y:2014 | 05 | 2014 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $1,623 | $7,000 | Not Implemented |
UD0913 # 12 Y:2014 | 12 | 2014 | TREAT AND REUSE RINSE WATERS | $15,837 | $10,000 | Not Implemented |
OK0888 # 09 Y:2014 | 09 | 2014 | OPTIMIZE PLANT POWER FACTOR | $9,969 | $6,825 | Not Implemented |
OK0888 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $1,977 | $0 | Implemented |
OK0888 # 06 Y:2014 | 06 | 2014 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $6,388 | $4,000 | Implemented |
OK0888 # 05 Y:2014 | 05 | 2014 | INSULATE BARE EQUIPMENT | $843 | $1,390 | Not Implemented |
OK0888 # 04 Y:2014 | 04 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,683 | $6,800 | Implemented |
OK0888 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $709 | $1,293 | Not Implemented |