Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

109

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0168 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $228 $195 Not Implemented
CO0169 # 06 Y:1989 06 1989 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,270 $250 Implemented
CO0169 # 05 Y:1989 05 1989 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $460 $87 Implemented
CO0169 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $280 $410 Implemented
CO0169 # 03 Y:1989 03 1989 INSTALL AUTOMATIC STACK DAMPER $1,770 $2,550 Implemented
CO0169 # 02 Y:1989 02 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,592 $455 Implemented
CO0169 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,441 $2,000 Implemented
MA0168 # 05 Y:1989 05 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $475 $305 Not Implemented
MA0166 # 03 Y:1989 03 1989 INSTALL TIMERS AND/OR THERMOSTATS $1,130 $180 Implemented
MA0168 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,218 $0 Implemented
MA0168 # 01 Y:1989 01 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $14,558 $10,000 Not Implemented
MA0168 # 04 Y:1989 04 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,362 $570 Implemented
MA0168 # 06 Y:1989 06 1989 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,664 $2,700 Not Implemented
MA0166 # 06 Y:1989 06 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,497 $908 Not Implemented
MA0166 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,628 $3,450 Not Implemented
MA0166 # 01 Y:1989 01 1989 ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE $19,320 $18,000 Not Implemented
MA0166 # 04 Y:1989 04 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $842 $1,700 Not Implemented
MA0166 # 05 Y:1989 05 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $21,230 $7,913 Not Implemented
KU0294 # 02 Y:1989 02 1989 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $16,418 $15,000 Not Implemented
KU0294 # 03 Y:1989 03 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $7,667 $8,200 Not Implemented
KU0294 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $903 $472 Implemented
KU0294 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,153 $4,100 Implemented
TN0381 # 06 Y:1989 06 1989 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,020 $4,820 Not Implemented
TN0381 # 05 Y:1989 05 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,846 $120 Implemented
TN0381 # 02 Y:1989 02 1989 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $16,038 $16,040 Not Implemented